DECLARATION OF COMPLIANCE
The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396 for the gas
part and with norm 73/23 for the electric part. The installation must be done observing the norms in force particularly
concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
GAS TECHNICAL DATA TABLE
NOMINAL BURNER CAPACITY kW
MODEL
DIMENS cm
7
10
Gas oven GN1/1
4 kW
TOT. NOM.
CAPACITY kW
GAS
COUPLING
ISO 7-1
PC1T-64G
40x60x29 h
/
1
/
10
R 1/2”
PC2T-68G
80x60x29 h
1
1
/
17
R 1/2”
PC3T-612G
120x60x29 h
1
2
/
27
R 1/2”
CF2-68G
80x60x90 h
1
1
1
21
R 1/2”
CF3-612GV
120x60x90 h
1
2
1
31
R 1/2”
CF2-68GEM
80x60x90 h
1
1
/
17
R 1/2”
CF3-612GEMV
120x60x90 h
1
2
/
27
R 1/2”
CFM2-68GEM
80x60x90 h
1
1
/
17
R 1/2”
CFM3-612GEMV
120x60x90 h
1
2
/
27
R 1/2”
ELECTRIC TECHNICAL DATA TABLE
MODEL
DIMENSIONS
cm
POWER
SUPPLY
TOTAL POWER
kW
MAX.
ABSORB. A
POWER SUPPLY
CABLE mm²
CF2-68GEM
80x60x90 h
230Vac 50/60 Hz
13,3
3,05
3x1,5
CF3-612GEMV
120x60x90 h
230Vac 50/60 Hz
13,3
3,05
3x1,5
CFM2-68GEM
80x60x90 h
230Vac 50/60 Hz
13,3
3,05
3x1,5
CFM3-612GEMV
120x60x90 h
230Vac 50/60 Hz
13,3
3,05
3x1,5
INSTALLATION
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
CHECKING FOR ADEQUATE VENTILATION
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
Installation rules
The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
• safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer’s instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
a) General indications (Rules valid for GB only)
- For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building