12
Ø
OUTPUT AND GAS CONNECTION FOR PLASMA CUTTING (
Figure A.3)
The plasma cutting torch and ground cable are supplied with the
plasma cutter. To connect the cables, turn the Power Switch “OFF”.
1.
Plug the major power connector (the widest wire) from the torch
cable to the “-” output terminal (8)
1
. Turn it clockwise using the
plastic safe protector until snug, do not over tighten.
2.
Plug the 2-prong connector from the torch cable into the 2-pin
socket (6). Turn the outer metal shell clockwise to tighten.
3.
Take off the cap of the “pilot arc” socket (7) on the inverter,
attach the connector with a metal chip from the torch cable to the
socket, put the cap back on and turn clockwise to tighten.
4.
Connect the ground cable & clamp to the “+” output terminal (5)
and turn it clockwise to tighten.
To minimize high frequency interference, refer to Machine Grounding and High Frequency Interference
Protection section of this manual for the proper procedure on grounding the work clamp and work piece.
To avoid receiving a high frequency shock, keep the plasma
cutting torch and ground clamp & cable Insulation in good
condition.
1
The number inside “( )” is the annotation in section Specifications – Controls and Setting.