A tracking solar array
The mounting pipe was extended to 11 feet (3
m), by welding it to a larger pipe. Wire is type
USE (outdoor rated). The wire is looped to
help it to shed water and to flex. Wires enter
the conduit through a “weather head”.
Courtesy of Dankoff Solar Products, NM, USA
Owners of a domestic water system watch as
the pump
fills their polyethylene storage tank.
The tank was buried later.
Photo courtesy of Dankoff Solar Products, NM, USA