10 Operation
Troubleshooting 11
Table 4: Troubleshooting guide
No output or LED on
Check that the input has been connected to a stable AC supply
Check that PV power is present
Check that the bottom PP2000S switch is in the “On” position
Check proper connections in terminals
Pump is not running with
PP2000S
Check for possible errors using PumpScanner
Check AC and PV supply
Check DC polarity on the controller side
Check wiring in general
Check that both the PowerPack and controller are switched on
‘Overvoltage’ warning in
PumpScanner with PS2-600
controller
Ensure that PV open circuit voltage is appropriate (see section 5.2)
Check the output voltage setting; choose lower voltage setting (see
section 4.1)
Pump is running at low power
during PowerPack operation
Check ambient temperature and ensure that the PowerPack has
proper ventilation
Check the output voltage setting (see section 4.1)
Test the controller using PV power. If there are still problems follow the PS2 troubleshooting guide.
6 Operation
Connect the AC power source and switch on the
PowerPack AFTER it has been connected to the pump
controller. When the controller and the PowerPack
are switched on, the system light should flash on
the controller and the pump should start. When
the PowerPack is switched OFF (or its AC source is
disconnected), the system will run with the PV power
available. If the LED indicator is on this means that
the PowerPack is activated.
7 Maintenance
This is a maintenance free device with no user-
serviceable parts inside. If you need assistance
please contact qualified service personnel.
8 Troubleshooting
Before contacting service personnel with
troubleshoorting questions, please follow the steps
outlined in table 4.