Table 4: Troubleshooting guide

No output or LED on

Check that the input has been connected to a stable AC supply

Check that PV power is present

Check that the bottom PP2000S switch is in the “On” position

Check proper connections in terminals

Pump is not running with 

PP2000S

Check for possible errors using PumpScanner

Check AC and PV supply

Check DC polarity on the controller side

Check wiring in general

Check that both the PowerPack and controller are switched on

‘Overvoltage’ warning in 

PumpScanner with PS2-600 

controller

Ensure that PV open circuit voltage is appropriate (see section 5.2)

Check the output voltage setting; choose lower voltage setting (see 

section 4.1)

Pump is running at low power 

during PowerPack operation

Check ambient temperature and ensure that the PowerPack has 

proper ventilation

Check the output voltage setting (see section 4.1)

Test the controller using PV power. If there are still problems follow the PS2 troubleshooting guide.

6  Operation 

Connect the AC power source and switch on the 
PowerPack AFTER it has been connected to the pump 
controller. When the controller and the PowerPack 

are switched on, the system light should flash on 

the controller and the pump should start. When 
the PowerPack is switched OFF (or its AC source is 
disconnected), the system will run with the PV power 
available. If the LED indicator is on this means that 
the PowerPack is activated.

7  Maintenance

This is a maintenance free device with no user-
serviceable parts inside. If you need assistance 

please contact qualified service personnel. 

8  Troubleshooting

Before contacting service personnel with 
troubleshoorting questions, please follow the steps 
outlined in table 4.