5.2 Connection and wiring
l
WARNING
- Only one of the power
sources must be connected at a time.
WARNING
– Beware of high voltage!
Hazardous electricity may be present
and can shock, burn or cause death!
Only authorized and qualified personnel
should operate the system.
a
CAUTION
– The PowerPack should
only be connected to power after correct
wiring or the controller might get
damaged.
CAUTION
- Do not connect the PV
modules to the DC output as it may
damage the PV modules.
AC Input
- Connect AC power to the terminals (L) line
and (N) neutral. Before connecting to grid, check that
the grid connection is properly protected with a fuse
and if required with an ELCB (Earth leakage circuit
breaker). All electrical connections must meet local
and national electrical standards.
Grounding
– Ensure the PowerPack is correctly
grounded to meet local and national ectrical
guidelines. The dedicated GND terminal on the AC
input is the grounding connection.
DC power out
- Connect the “DC OUT” of the
PowerPack and the output of the PV generator to the
controller; each via its own PV disconnect. Pay close
attention to the polarity. Install a properly rated DC
disconnect switch between the solar generator and
the pump controller as well.