6          Application

Installation          7

Figure 2: Voltage switch selector 

Increasing the voltage above the pre-configured level 

may result in interactions between the controller and 
the PowerPack that cause stops and restarts. In this 
case, reduce the voltage setting. 

This setting should only be modified by professional 

personnel and is the user’s own responsibility. 
LORENTZ recommends keeping the default value and 
provides further technical suggestions in table 2.

COMPASS can be used to check the expected 
performance of your system based on the selected 
voltage setting.

4.2 

Remote On/Off function

This PowerPack includes a normally open (NO) 
terminal for remote control. Closing the contact 

between the remote on/off terminals will switch off 

the DC output of the PowerPack.

Note: This feature does not offer a dedicated 

automatic control function in combination with the 
PS2-4000. 

5  Installation

 

l

WARNING 

– This device is to be 

installed, connected and serviced by 
qualified personnel only. Ensure all power 
sources are disconnected when making 
connections to this unit. Follow all 
appropriate electrical codes.

WARNING 

- For best performance 

and to avoid over temperature shut off, 
install the PowerPack in a location that 
is shaded from direct sun.  Allow free 
air circulation around the ventilation 

openings on the side and bottom of 

enclosure. 

Summary of Contents for 19-000185

Page 1: ...ent 16 A Frequency 47 63 Hz OUTPUT DC Rated voltage 210 250 V Rated current 12 14 A OPERATING CONDITIONS Operating temperature ambient 20 to 45 C SN UL62368 1 l WARNING Electric shock hazard dangerous...

Page 2: ...nces When installing and using the electrical equipment basic safety precautions should always be followed including the following l WARNING To reduce the risk of injury do not permit children to use...

Page 3: ...n Germany Safety directions for maintenance inspection and assembly work It is the user s responsibility to ensure that all maintenance inspection and assembly work is performed exclusively by authori...

Page 4: ...V AC 16 A 230 V AC Frequency 47 63 Hz DC Out 210 250 V DC 12 14 A Working Ambient Temp 20 45 C 4 F to 113 F IP Class IP33 Remote Control On Off control function Protections Short circuit overload over...

Page 5: ...AC power supply to the PowerPack in cases where scheduled use of the PowerPack is necessary e g to extend pumping time Figure 1 System layout The PowerPack can be remotely activated through its remote...

Page 6: ...ection DC voltage value Description Pos 1 210 V Default position that secures operation for all PS2 4000 pump systems Pos 2 223 V Applicable for most C SJ pumps and lifts Pos 3 233 V Applicable for mo...

Page 7: ...te On Off function This PowerPack includes a normally open NO terminal for remote control Closing the contact between the remote on off terminals will switch off the DC output of the PowerPack Note Th...

Page 8: ...The unit must be protected from direct rainfall and direct sunlight Fixing pattern for holes 310 x 292 mm 12 2 x 11 5 in Figure 3 Product dimensions A D B E C F A 280mm B 350mm C 140mm D 334mm E 384mm...

Page 9: ...the terminals L line and N neutral Before connecting to grid check that the grid connection is properly protected with a fuse and if required with an ELCB Earth leakage circuit breaker All electrical...

Page 10: ...power has been disconnected When the controller and the PowerPack are switched on the system light should flash on the controller and the pump should start When the PowerPack is switched off or its AC...

Page 11: ...ller side Check the wiring and ensure that the PV array is disconnected Check that both the PowerPack and controller are switched on Pump is stopping frequently during PowerPack operation Check AC sup...

Page 12: ...V210702 www lorentz de Sun Water Life...

Reviews: