6 Application
4.1 Voltage selection
l
WARNING
– Before changing power
sources, the PowerPack and controller
must be switched off and the AC and DC
power sources must be disconnected.
WARNING
– The following feature
should only be operated by qualified
personnel.
Table 2: Optional voltage selection
Voltage
selection
DC voltage
value
Description
Pos 1.
210 V
Default position that secures operation for all PS2-4000 pump systems
Pos 2.
223 V
Applicable for most C-SJ pumps and lifts
Pos 3.
233 V
Applicable for most C-SJ pumps and lifts
Pos 4.
250 V
Recommended only for HR pumps
The PowerPack comes pre-configured to a voltage of
210 V DC in position 1 which is safe to work with all
PS2-4000 systems under all conditions. However, in
many applications this voltage can be set to a higher
value as written in table 2.