Lorentz 19-000185 Manual For Installation And Operation Download Page 10

10          Operation

6  Operation

Ensure that only one power source at a time is 
connected. Connect the AC power source and 
switch on the PowerPack AFTER it has been 
connected to the pump controller and DC power 
has been disconnected. When the controller and the 
PowerPack are switched on, the system light should 

flash on the controller and the pump should start. 
When the PowerPack is switched off (or its AC source 

is disconnected), the solar array can be reconnected.

7  Maintenance 

This is a maintenance free device with no user-

serviceable parts inside. Contact qualified service 

personnel for assistance.

Summary of Contents for 19-000185

Page 1: ...ent 16 A Frequency 47 63 Hz OUTPUT DC Rated voltage 210 250 V Rated current 12 14 A OPERATING CONDITIONS Operating temperature ambient 20 to 45 C SN UL62368 1 l WARNING Electric shock hazard dangerous...

Page 2: ...nces When installing and using the electrical equipment basic safety precautions should always be followed including the following l WARNING To reduce the risk of injury do not permit children to use...

Page 3: ...n Germany Safety directions for maintenance inspection and assembly work It is the user s responsibility to ensure that all maintenance inspection and assembly work is performed exclusively by authori...

Page 4: ...V AC 16 A 230 V AC Frequency 47 63 Hz DC Out 210 250 V DC 12 14 A Working Ambient Temp 20 45 C 4 F to 113 F IP Class IP33 Remote Control On Off control function Protections Short circuit overload over...

Page 5: ...AC power supply to the PowerPack in cases where scheduled use of the PowerPack is necessary e g to extend pumping time Figure 1 System layout The PowerPack can be remotely activated through its remote...

Page 6: ...ection DC voltage value Description Pos 1 210 V Default position that secures operation for all PS2 4000 pump systems Pos 2 223 V Applicable for most C SJ pumps and lifts Pos 3 233 V Applicable for mo...

Page 7: ...te On Off function This PowerPack includes a normally open NO terminal for remote control Closing the contact between the remote on off terminals will switch off the DC output of the PowerPack Note Th...

Page 8: ...The unit must be protected from direct rainfall and direct sunlight Fixing pattern for holes 310 x 292 mm 12 2 x 11 5 in Figure 3 Product dimensions A D B E C F A 280mm B 350mm C 140mm D 334mm E 384mm...

Page 9: ...the terminals L line and N neutral Before connecting to grid check that the grid connection is properly protected with a fuse and if required with an ELCB Earth leakage circuit breaker All electrical...

Page 10: ...power has been disconnected When the controller and the PowerPack are switched on the system light should flash on the controller and the pump should start When the PowerPack is switched off or its AC...

Page 11: ...ller side Check the wiring and ensure that the PV array is disconnected Check that both the PowerPack and controller are switched on Pump is stopping frequently during PowerPack operation Check AC sup...

Page 12: ...V210702 www lorentz de Sun Water Life...