5.  Oscillation setting: The heater will oscillate by pressing the oscillation key      once. To stop the oscillation, 
 

press this key again. This key is only valid when the heater is working.

6.  Timer setting: When the heater is on, it can be set to turn off automatically in 0.5 to 9.5 hours.
  

     Press the Timer key. The display will blink.

  

     Press the Increase key     and Decrease key     to set the desired time for the unit to turn off.

  

     After settings have been made, the display will change back to show the room temperature.

  

     To cancel the timer, press the timer pad and press the Increase key     and Decrease key     until 0.0 

 

 

      appears in the display.

  

     If the timer was set before the power outage, it will need to be reset after power is restored.

NOTE:

  Every time the heater is switched on, it will heat at high temperature for 2 minutes. The heater will then 

operate according to the instructions below. When the room temperature reaches the desired set temperature
or if the set temperature is lower than or equal to the room temperature, the heating element will shut off 
immediately. However, the fan motor will continue to run for about 15 seconds before shutting off. This is a safety 
feature that is designed to protect the unit from overheating. 

USING THE REMOTE CONTROL

The remote has 6 keys that have following functions:

Inserting Batteries:

  Press down on the battery compartment cover and slide out.

  Insert the batteries, making sure that the positive terminals are facing the proper direction marked inside  

 

the battery compartment.

  Close the cover by sliding it in.

Notes: 
 

1.  Use 2 "AAA" batteries (NOT INCLUDED)

 

2.  Do not mix old and new batteries

 

3.  Do not mix alkaline, standard (carbon-lined)  

 

 

or rechargeable (nickel-cadmium) batteries

 

4.  Remove the batteries from remote if it is  

 

 

to be left unused for a long period of time. 

CAUTION:

 This heater includes an Overheat Protection System that shuts the unit off if it overheats due to 

abnormal conditions. If this occurs, turn the heater off, unplug it, and check for and remove any objects on or 
adjacent to the heater. Allow it to cool for a few minutes, plug it back in, and resume normal operation.

CAUTION:

 This heater includes a safety tip-over protection feature, which will shut the heater off in case it is 

tipped over. If, at any time, the heater does tip over, please put the heater back in the upright position. The heater 
will resume its normal operation.

TROUBLESHOOTING

If the heater fails to operate, please follow these instructions:
  

     Ensure that your circuit breaker or fuse is working properly.

  

     Ensure that the heater is plugged in, and that the electrical outlet is working properly.

  

     Check for obstructions. If an obstruction is detected, turn the heater off. Unplug the heater, and wait  

 

 

      a few minutes for it to cool down. Carefully remove the obstruction. Plug the heater back in and turn it  

 

 

      on, referring to the instruction manual.   

Press to switch the heater on, press again to switch off

Press this key to set the timer

Press this key to start or stop the oscillation

Press this key to select the desired mode (HI-LO      ) to return to standby mode

Value adjustment key, press it to increase temperature setting or increase timer setting

Value adjustment key, press it to decrease temperature setting or decrease timer setting

Remote

Battery

Cover

Summary of Contents for LLR84161

Page 1: ...Ceramic 23 Tower Heater LLR84161 READ AND SAVE THESE INSTRUCTIONS Customer Service 1 866 646 4332...

Page 2: ...ded to fit only one way in a polarized outlet If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat this safet...

Page 3: ...and heating elements operate at 1500 W 4 Temperature setting When the heater is set to HI or LO press the UP key and DOWN key to set the desired temperature between 5 C to 35 C in increments of 1 C I...

Page 4: ...sliding it in Notes 1 Use 2 AAA batteries NOT INCLUDED 2 Do not mix old and new batteries 3 Do not mix alkaline standard carbon lined or rechargeable nickel cadmium batteries 4 Remove the batteries fr...

Page 5: ...nce during the operation season in order to maintain an optimum level of performance Always be sure to turn the power off and unplug the heater before cleaning Be sure to save the box for off season s...

Page 6: ...Appareil de chauffage c ramique 23 pouces tour LLR84161 LISEZ ET CONSERVEZ CES INSTRUCTIONS Service la client le 1 866 646 4332...

Page 7: ...Cet appareil est dot d une fiche polaris e une lame est plus large que l autre afin de r duire les risques de choc lectrique Il n y a qu une seule mani re d ins rer cette fiche dans une prise polaris...

Page 8: ...lement circuler l air de la pi ce Les l ments chauffants restent teints LO faible le ventilateur et les l ments chauffants fonctionnent 900 W HI lev e le ventilateur et les l ments chauffants fonction...

Page 9: ...outefois le moteur du ventilateur continue tourner pendant une quinzaine de secondes avant de s teindre Ceci est un dispositif de s curit dont le r le est d viter que l unit ne surchauffe UTILISATION...

Page 10: ...Ne jamais tenter d ouvrir ou de r parer soi m me cet appareil de chauffage Faute de quoi vous annuleriez la garantie et pourriez endommager la machine ou m me vous blesser Si le probl me persiste veu...

Page 11: ...Calefactor de Cer mica Tipo Torre de 23 LLR84161 LEA Y CONSERVE ESTE INSTRUCTIVO Atenci n al cliente 1 866 646 4332...

Page 12: ...Si aun as no se ajusta acuda con un electricista calificado NO intente alterar esta caracter stica de seguridad Si lo hace podr a existir el riesgo de un choque el ctrico 10 Para desconectar el calefa...

Page 13: ...entilador solamente hace circular el aire por la habitaci n los elementos de calefacci n est n apagados LO El ventilador y los elementos de calefacci n operan a 900 W HI El ventilador y los elementos...

Page 14: ...e sin embargo el motor del ventilador seguir funcionando por alrededor de 15 segundos antes de apagarse sta es una caracter stica de seguridad que est dise ada para proteger la unidad de un sobrecalen...

Page 15: ...ara seguir las instrucciones correspondientes No intente abrir ni reparar el calefactor por su cuenta de lo contrario podr a invalidar la garant a y causar da os o lesiones personales Si el problema p...

Reviews: