22
G-Link-200-OEM
USER MANUAL
•
Continuous
- Collect data continuously at the configured sample rate. All data is transmitted
and/or logged to flash memory until a Set to Idle command is received.
•
Limited
- Automatically stop sampling and return to Idle mode after the configured time
duration is met.
•
Periodic Burst
- Perform short sampling bursts at periodic intervals. This operation allows
longer battery life and increased network sizes in applications where continuous monitoring
is not required.
•
Event Triggered
- Collect data continuously at a fixed sample rate. However, only transmit
or log data if one of the configured threshold conditions has been met. When the condition is
met, all active sensor channels transmit and/or log both pre- and post-event data. Benefits of
this operation include increased battery life, reduced data sets, and increased network size.
Figure 21. Event Triggered Sampling