Troubleshooting
- 67 -
02.20
909.2710.1-06
code
designation
reason
removal
E 29
EEProm checksum error
data in EEPROM memory faulty/cor-
rupt
switch the machine off and on again,
exchange the MAPRO if necessary
E 30
Mains undervoltage 2
power unit 2 detected a too low bus
voltage
check mains voltage, mains rectifier,
pc-board PWRUP and DCDR
E 31
Communication error
Master is not responding to Process
switch the machine off and on again,
exchange pc-board MAPRO if neces-
sary
“?”
the display only shows “?“ the display doesn‘t get any data from
the MAPRO
mains phase is missing
–
no CAN bus connection between pc-
board DMR and pc-board MAPRO
–
check flat ribbon cable betwenn
MAPRO and DMR or control cable of
interpass hose package
–
check all phases from mains supply
“nop” no program
no welding parameters available for
selected material-wire-gas combina-
tion (no reasonable combination)
select other material-wire-gas combi-
nation
CFG
ERR
“CFG ERR” is shown in
volt/amps display
wrong front panel connected (only at
P Basic)
connect the correct front panel (pc-
board MAT-BF)
blinking volt/amps display Overload, the power unit was electri-
cally overloaded, the machine is limit-
ing the max. power output
indication goes away together with the
hold LED
(*1) display the module temperatures in menu Extras > Diagnosis > Module temperatures
(*2) display the supply voltages in menu Extras > Diagnosis > Operating voltages
(*3) display the flow rate in menu Extras > Diagnosis > Flow rate cooling system
(*4) display the motor current in menu Extras > Diagnosis > W.Feeder motor current
(*5) display the configuration in menu Extras > Machine data > Configuration