![LORCH P-Basic Service Manual Download Page 53](http://html.mh-extra.com/html/lorch/p-basic/p-basic_service-manual_1939304053.webp)
Troubleshooting
- 53 -
02.20
909.2710.1-06
Flow meter
The most common cause of a cooling water fault “E05” is a dirty flow meter. Regular cleaning of the com-
plete cooling circuit (torch, intermediate hose package, internal hoses, cooler) is recommended. Depend-
ing on the degree of pollution, the coolant tank should be completely washed out, as dirt can accumulate
at the bottom of the tank over time.
to open the flow meter, turn the housing
halves against each other (bayonet assem-
bly)
take off the top halve
take out sealing ring and the turbine
!!! CAUTION !!!
mind the right flow direc-
tion, do not reverse in- and
output when mounting the
flow meter back into the
machine