Troubleshooting
- 64 -
02.20
909.2710.1-06
9.15 Malfunction Codes
code
designation
reason
removal
E 01
Thermal overload
thermal sensor of power unit meas-
ures a too high temperature
let machine cool down in standby (*1)
E 02
Mains overvoltage
mains voltage too high
internal 24V supply > 36V
check mains voltage and control
transformer (*2)
E 03
Secondary overcurrent
welding current is too high (>120%)
check current sensor and its wiring
E 04
Stop/ Peripherals error
sub code
-01
PE protection has detected a current
>15A flowing via the protective earth
wire of the mains cable
–
check if the welding wire has con-
tact to metal parts of the housing or
parts with PE potential (wire spool
installation)
–
check X26 on MAPRO board
–
switch the machine off and on again
to reset the error message
Stop/ Peripherals error
sub code
-02
the gas pressure switch (optional
feature) has opened: not enough gas
pressure left
–
check / replace the gas bottle
–
check X26 on MAPRO board
–
switch the machine off and on again
to reset the error message
Stop/ Peripherals error
sub code
-03
the gas flow rate is too low (only pos-
sible with installed flow sensor)
–
check gas supply
–
check min.gas flow setting in
customize menu
E 05
Cooling system error
flowrate of the cooling liquid is too
low (< 0.3 l/min)
–
pump is not working
–
check level of cooling liquid and
flowrate (*3)
–
check connectors of flow-meter
–
check fuse SI7 (4A) on MAPRO
–
check all hoses incl. torch and inter-
pass hose
E 06
Secondary overvoltage
Master detects output voltage is too
high (>100V)
check wiring of power unit
E 07
EEProm checksum error
no welding program stored or error
during reading from memory
switch the machine off and on again,
if necessary transfer the welding pro-
grams to machine again
E 08
Wire feed / tacho
–
power consumption of wire feed
motor too high
–
tacho not connected to DMR X5
–
CAN-Bus connection between
MAPRO and DMR is interfered/
blocked
–
blow out torch package with com-
pressed air
–
check wire feed unit
–
check motor current (*4)
–
check wiring of wire feed motor and
pc-board DMR
–
check interpass hose package
M01
Motor overvoltage
(only at DMRPP)
supply voltage for motor driver is too
high (70V DC > 130V DC)
–
check control transformer
–
check motor supply
M02
Motor op. voltages
(only at DMRPP)
supply voltage for motor driver is too
low (70V DC < 30V DC)
–
check control transformer
–
check motor supply
M03
Motor 1 overcurrent
(only at DMRPP)
wire feed motor draws too much cur-
rent
–
check wire feed unit and motor
–
check motor current (*4)