![LORCH P-Basic Service Manual Download Page 14](http://html.mh-extra.com/html/lorch/p-basic/p-basic_service-manual_1939304014.webp)
Front panels
- 14 -
02.20
909.2710.1-06
6.3
Front panel P-basic
2s
Quatro
sec
Hold
m/min
6
7
8
Fig. 5:
Front panel P-Basic
Gas test
–
keep the torch trigger pressed
–
switch on the machine with the pressed trigger switch
–
the gas valve is switched on for 30 sec.
Pump test
–
press the button “operating mode”
[
6
]
and “program selection”
[
7
]
together at the same time
–
the water pump is switched on for one minute
–
press both buttons again to switch off the pump manually
Reset
–
keep the buttons “program selection”
[
7
]
and the button “main parameter”
[
8
]
pressed for about
five sec.
–
all parameters are reset to factory settings