Commissioning
909.2759.9-00
- 27 -
02.16
14.4 Call secondary parameters
(ControlPro)
Â
Select the desired operating mode with button 16.
9
LED 13, 14 or 15 is lit.
Â
Press button 16 for 2 sec.
9
The parameter code and the associated setting value
are shown in turn in the 7-segment display 19.
Â
Select the desired secondary parameter by turning the
rotary knob 12.
Â
Confirm the secondary parameter by pressing the
control knob 12.
9
The setting value flashes in the 7-segment display 19.
Â
Set the desired value by rotating the control knob 12.
Â
Confirm the setting by pressing the control knob 12.
Â
Select the next secondary parameter by turning rotary
knob 12 or exit the secondary parameters by pressing
button 16.
Different secondary parameters are available depend-
ing on the selected operating mode.
Code
Parameter
Standard value
Setting range
Mode
CEL
MMA
TIG
AEd Arc end detection
(%)
100
0...200
x x
dAF Arc Force (%)
100
0...200
x x
Sbt
Auto-Standby
time (min)
30
Off,
5...30
x x x
StE
Hotstart (%)
125
5...200
x x
Start current (%) 50
5...200
x
Stt
Hotstart time (s)
1
0...20
x x
Start current
time (s)
0.1
0...20
x
rEd
Display version
number
-
-
x x x
rEL
Master version
number
-
-
x x x