Messages
909.2759.9-00
- 29 -
02.16
16.2 Error message (ControlPro)
An error code is displayed in the 7-segment display in
the event of a malfunction. The sub-error (Sub-Code)
is displayed by pressing button 16
As long as there is an error code on display
welding is not possible.
Code
Error
Cause
Possible remedy
E01-1
Excess temperature
Sec. diode was overheated
Allow the system to cool
down in standby, check the
ventilation system
E01-2
Primary module was overheated
E01-3
Transformer overheated
E01-4
The equipment has been overheated
E02-2
UZK overvoltage
UZK voltage too high on start-up
Check mains voltage
E02-3
UZK voltage too high in DSP
E02-4
UZK voltage too high in prim. processor
E02-5
UZK voltage too high in FPGA
E06-0 Overvoltage
Initial voltage too high
Contact Service Department
E07-1
EEPROM
EEPROM faulty during initialisation
Switch the equipment off and
on again
E07-2
EEProm access error
E09-0 Voltage detection
Voltage measuring system faulty
Contact Service Department
E12-0 Power unit
Power section start-up faulty
Contact Service Department
E13-1
Temperature sensor
Thermal sensor of sec. diode not ready for operation
Contact Service Department
E13-2
Thermal sensor of primary module not ready for
operation
E13-3
Thermal sensor of transformer not ready for operation
E14-0
Supply voltage
Internal supply voltage too low
Check mains voltages
E14-1
Internal supply voltage too low on start-up
E15-0
Current measurement
Error during current measurement
Contact Service Department
E15-1
Error during current measurement FPGA
E18-2 Overload protection
Safety switch device to protect electrical components
during welding without load
Allow the equipment to cool
down in standby
E22-3 Mains undervoltage
Mains voltage on power unit is too low on start-up
Check mains voltages
E25-0 VRD
Voltage Reduction Device (VRD) defective
Contact Service Department
E31-4 Communication
FPGA communication faulty
Contact Service Department
E32-1
FPGA
FPGA overcurrent
Contact Service Department
E32-2
FPGA timeout
E32-4
FPGA IP Max Error
E33-1
Power unit
Power unit module not symmetrical
Contact Service Department
E33-2
Power unit module not symmetrical on start-up
E34-0
Fan
Fan current too high
Contact Service Department
E34-1
Fan current too low
i