6. Cleaning, Care and Maintenance

– Remove the filter, which protects the fan against dust and dirt, from time to

time and clean it.

– After  several  hours  of  operation,  some  droplets  of  condensation  will  have

formed at the nozzle. That is normal and not a malfunction.

Please note

: Remove fluid droplets at the nozzle only when the machine has

completely cooled off. During operation the nozzle gets very hot!

– Do not let the 

Unique

2

 run without any fluid as the pump will run dry.

– Check the state of the fluid filter [12] from time to time and clean or replace it

when necessary.

PLEASE NOTE

: The vaporizer of our machines does not have to be cleaned!

Cleaners, available on the market, can damage the vaporizer! We cannot grant
warranty in this case.

Trouble:

The pump runs, but little or no haze is produced.

Cause:

The pump sucks no or too little fluid.
· Check whether the canister is empty
· Check whether the brass collar is properly connected with the brass
  coupling
· Check whether the fluid filter in the canister is clogged
· Check whether the fluid tube is twisted or defective

Trouble:

The yellow LED at the machine does not light up (when running
via DMX)

Cause:

Connection from the machine to the desk is faulty.
· Check whether the plug is plugged in correctly
· Check whether the cable is defective
· Check whether the DMX start address is adjusted correctly

Trouble:

During operation the 

Unique

2

 fails to work for a long time

Cause:

The overtemperature protection device is activated.
· Check whether the fan is clogged

7. Troubleshooting

Summary of Contents for LMAF LOOK

Page 1: ...1 Operating manual a Look Solutions product...

Page 2: ...icon tube and air valve filter 1 canister of UNIQUE fluid 2l 1 manual As an option XLR remote for analog control delivered without cable Diverter Case Hanging set Radio remote for starting the HDCS pr...

Page 3: ...l choices 5 4 1 Control via DMX 512 5 4 1 1 Adjusting the DMX start address 5 4 1 2 Adjusting the pump and the fan 5 4 2 Control via 0 10 Volt DC 5 4 2 1 Adjusting the pump and the fan 5 4 3 Stand alo...

Page 4: ...t haze creating the right atmosphere and is greatly enhancing lighting effects The pump and the fan are fully and separately controllable giving the Unique2 a good level of noise reduction The machine...

Page 5: ...not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor should you have accidentally swallowed some fluid Spilled fluid or splashed flui...

Page 6: ...s warranty and can be dangerous to your health Never use cleaner or fragrances with this machine P 2 5 Rear view 2 6 Front view 7 Nozzle Vapour and nozzle area extremely hot Do not touch Do not cover...

Page 7: ...al dealer Fluid also comes in 10 and 25 litre canisters and barrels with 220 litres To guarantee trouble free operation the special UNIQUE Fluid must be used Use of other liquids will void the manufac...

Page 8: ...ml min Pump value 4 2 Changing the fluid bottle Disconnect the fluid tube from the lid by retracting the brass collar 9 and removing the brass coupling 11 Remove the container from the tank housing of...

Page 9: ...luted air be free from vibrations be a non flammable place or surrounding be well ventilated with haze free air keeping the ambient operating tempera ture between 50 F and 105 F and the relative humid...

Page 10: ...a 5 6 7 level b timer profile F 7 5 Fig 1 Adjusting the pump output 5 3 Switching the device off a Press the Mode button 14 till OFF appears on the display After 15 Seconds the machine will switch off...

Page 11: ...e data can be readjusted whenever you want to You may control the Unique2 externally through the XLR sockets 2 and 3 Please note DMX takes priority That means when the machine is controlled via DMX 51...

Page 12: ...Press the Mode button 14 at the control panel until a P and two figures appear on the LED display 17 see Fig 1 Put the pump up to 99 b Press the Mode button 14 at the control panel until an F and two...

Page 13: ...Stand alone mode In this mode all data for the pump and the fan must be adjusted directly at the machine 5 4 4 Haze Density Control System HDCS dmxin active XXX address PXX pump FXX fan P pause min F...

Page 14: ...To leave the HDCS menu or quit the Profile first press the Mode button until ESC appears on the display Fig 9 Then press the Enter button 16 once to return to the main menu 5 4 4 1 Using the Profile 5...

Page 15: ...sting the haze time Time min Pump Fan 1 4 7 6 5 Pause Run Time Level A Run Time Level B 3 2 Level A Level B dmxin active XXX address PXX pump FXX fan P pause min F fogtime sec 1 pause 2 3 4 level a 5...

Page 16: ...can be adjusted in per cent 0 99 To start the Timer Mode press and hold the Mode button 16 for more than 2 Seconds The red Timer Profile LED 19 will blink as soon as the machine has switched to the Ti...

Page 17: ...on the market can damage the vaporizer We cannot grant warranty in this case Trouble The pump runs but little or no haze is produced Cause The pump sucks no or too little fluid Check whether the cani...

Page 18: ...e in Germany 7 Troubleshooting E 1 E 8 Trouble E 4 appears on the LED display Cause The machine is getting too hot The heating switches off and the machine cools down Solution Disconnect the machine f...

Page 19: ...ntee services if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are nor approved by us The right of guarantee service is also lost if flu...

Page 20: ...20 a Look Solutions product...

Reviews: