![background image](http://html1.mh-extra.com/html/look-solutions/lmaf-look/lmaf-look_operating-manual_1938894014.webp)
14
a) Press the Mode button repeatedly [14], until „Pro“ appears on the display (see
Fig. 4).
b) Press the Enter button [16] once to switch to the HDCS Menu. The red Timer/
Profile-LED [20] will be lit.
c) Adjust settings 1 to 7 according to the chart on page 15, using the Up/Down
buttons [15] and pressing the Mode button to switch between the settings.
These settings are stored in non-volatile memory. You don‘t have to run the
Profile or press the Enter button in order to „save“ the settings. All settings
can be changed as described at any time.
d) To start the Profile with the adjusted values, press the Mode button [14], until
„run“ appears on the display (Fig. 8), then press the Enter button [16].
The Timer/Profile-LED [20] flashes, indicating that the Profile is running. The
green Active-LED [18] lights as soon as the adjusted Pause (Pre-Runtime) has
passed and level A has started. The Profile can also be started via an optional
radio remote.
e) To leave the HDCS menu or quit the Profile, first press the Mode button until
„ESC“ appears on the display (Fig. 9). Then press the Enter button [16] once to
return to the main menu.
5.4.4.1 Using the Profile
5. Operating the Unique
2
The following Profile settings can be programmed:
1. Pause (Pre-Runtime)
0 - 99 min
2. Pump (Level A)
1 - 99 %
3. Fan (Level A)
1 - 99 %
4. Run-Time (Level A)
0 - 99 min
5. Pump (Level B)
1 - 99 %
6. Fan (Level B)
1 - 99 %
7. Run-Time (Level B)
0 - 99 min
The HDCS allows you to program a profile for a show. You can set two output
levels and a run-time for each, along with an initial Pause-time.
A Profile consists of seven settings: Setting #1 is the pause-time, settings #2 - 4
are for Level A (pump, fan and run-time), and settings #5 - 7 are for Level B
(pump, fan and run-time).
For example
: You want the machine to run at full output (P 99% / F 99%) for 10
Minutes immediately before the show begins (Level A), and then you want the
machine to run at a lower output (P 05% / F 50%) for the duration of the 60
Minutes show (Level B). Program these two Levels into the HDCS profile, along
with a 20 Minute pause-time. Activate the Profile 30 Minutes before each show.