5.4 Control choices
dmx
in
active
XXX
= address
·
PXX
= pump
·
FXX
= fan
P
. = pause
(
min
) ·
F.
= fogtime
(
sec
)
1. =
pause
·
2./3./4. =
level a
·
5./6./7. =
level b
timer
profile
P 1 5
Fig. 2: Adjusting the fan output
Fig. 3: Adjusting the DMX-start address
14: Mode button
15: Up/Down button
16: Enter button
17: Led display
18: Active-LED, green
19: DMX-LED, yellow
dmx
in
active
XXX
= address
·
PXX
= pump
·
FXX
= fan
P
. = pause
(
min
) ·
F.
= fogtime
(
sec
)
1. =
pause
·
2./3./4. =
level a
·
5./6./7. =
level b
timer
profile
2 7 5
20: Profile/
Timer-LED, red
dmx
in
active
XXX
= address
·
PXX
= pump
·
FXX
= fan
P
. = pause
(
min
) ·
F.
= fogtime
(
sec
)
1. =
pause
·
2./3./4. =
level a
·
5./6./7. =
level b
timer
profile
F 7 5
Fig. 1: Adjusting the pump output
5.3 Switching the device off
.
a. Press the Mode button [14] till „OFF” appears on the
display. After 15 Seconds the machine will switch off
automatically. On the right bottom edge of the display
a red decimal point will appear.
You can also switch off the machine within these 15 Seconds by pressing the
Enter button [16].
b. When you switch off the DMX signal, the machine will be switched off
automatically after 15 Seconds.
Note
:
Please make sure that the
Unique
2
will not be disconnected too early to allow
the fan to run until the device has cooled down. This will ensure that no fluid
remains in the vaporizer to come out as droplets when the device is switched
on next time.
5. Operating the Unique
2