13
4. Management guide
This section instructs you how to enter and set up the configurations, which can be accessed
by RS-232 serial port (out-of-band) on the rear panel or by Internet Browser over the network
(in-band).
Factory Default value:
IP
:
192.168.1.1
Subnet Mask
:
255.255.255.0
Default Gateway
:
192.168.1.254
4.1 Access the Switch
Console Port (Out-of-band) connection
The operating mode of the console port is:
DCE
115200 (Fix baud rate)
n (No parity checking)
8 (8 Data bits)
1 (1 stop bit)
None (No flow control)
After attaching a RS-232 cable (Straight-through) to the serial port of a PC running a
terminal emulation program, press
“Enter”
key then login screen appears. Enter your
username and password to login the management console.
Note
:
For the detail Command line Interface instructions, please refer to the Appendix in
chapter 6
Attention
:
1.
The factory default value of UserName and Password is
“admin”
2.
System configurations via the Console Port only will be allowed
by the way of master device