LongerPump BT100-1F Operating Manual Download Page 5

1

Operation Panel

2

Star t/Stop Key

Exit Key

Direction Key

Prime Key

Knob

S 1

S 2

P 3

P 2

P 4

P 1

LCD Display

Power Switch

Introduction

Applicable pump heads for BT100-1F are YZ1515x, YZ2515x, YZII15, YZII25 and
DG-1, DG-2, DG-4. The pump delivers flow rates from 0.16

L to 500 mL / min

and dispensing volume is from 0.01 mL to 9.99 L. Combining 128

32 LCD

display with membrane keypad and rotary coded switch makes the operation
easy and prompt. The speed can be adjusted manually or automatically through
external control interface.

μ

×

Note:

Ref. page 11 to know detailed external control function.

The pump must be grounded properly before operating in order to protect the
operator in moist environment.

S

Standard Configuration

S1 Pump Head
S2 Drive

P

Par t

P1

Signal Output Por t

P2

External Control Input Por t

P3

Power Socket

P4

Infuse Holder

Basic Operation

Start/Stop Key

Direction Key

Knob

Knob

Knob

Knob

Prime Key

Prime Key

Prime Key

Exit Key

Exit Key

Power Switch

Press to star t or stop the pump

Press to change the rotation direction of the pump

Function 1: Turn the

to adjust flow rate under none-prime working status.

Function 2: Menu selection function, turn the

to select menu and set the

parameters, press

to confirm the selection.

In common state, press the

to enter prime state when the pump runs

at full speed for empting, filling and rinsing operation; Press the
again to return to common state. In prime state, other keys are invalid.

Function 1: Cancel current operation and return to previous menu.

Function 2: In dispensing working mode, press

to check current speed

and the needed time for dispensing the set volume.

Turn on or off the pump.

BT100-1F OPERATING MANUAL

BT100-1F OPERATING MANUAL

Summary of Contents for BT100-1F

Page 1: ...Longer Precision Pump Co Ltd ADD Building A Chuangye Center Baoding National High Tech Industrial Development Zone Baoding Hebei China 071051 TEL 86 312 3110087 3138553 FAX 86 312 3168553 E mail longe...

Page 2: ...Specification 1 2 2 3 3 3 4 5 5 6 6 6 6 7 7 8 8 8 8 9 9 9 9 10 11 11 12 14 14 15 15 15 16 11 IMPORTANT INFORMATION Please read operation manual carefully before operation WARNINGS Tubing breakage may...

Page 3: ...Specification 1 2 2 3 3 3 4 5 5 6 6 6 6 7 7 8 8 8 8 9 9 9 9 10 11 11 12 14 14 15 15 15 16 11 IMPORTANT INFORMATION Please read operation manual carefully before operation WARNINGS Tubing breakage may...

Page 4: ...1 Signal Output Port P2 External Control Input Port P3 Power Socket P4 Infuse Holder Basic Operation Start Stop Key Direction Key Knob Knob Knob Knob Prime Key Prime Key Prime Key Exit Key Exit Key Po...

Page 5: ...1 Signal Output Port P2 External Control Input Port P3 Power Socket P4 Infuse Holder Basic Operation Start Stop Key Direction Key Knob Knob Knob Knob Prime Key Prime Key Prime Key Exit Key Exit Key Po...

Page 6: ...e flow rate b Current speed Display current speed the can increase or decrease the speed c Running direction Indicate the direction of the pump d Running status stands for pump running stands for pump...

Page 7: ...e flow rate b Current speed Display current speed the can increase or decrease the speed c Running direction Indicate the direction of the pump d Running status stands for pump running stands for pump...

Page 8: ...ump is running Pump head and tubing setting Press the to enter interface press again to enter submenu of then press again the pump will show all the suitable pump head turn to select needed pump head...

Page 9: ...ump is running Pump head and tubing setting Press the to enter interface press again to enter submenu of then press again the pump will show all the suitable pump head turn to select needed pump head...

Page 10: ...uence the filling accuracy Set Press and turn to highlight the back suction time line Press the to enter next interface turn to adjust press to confirm or press to cancel the adjustment and return to...

Page 11: ...uence the filling accuracy Set Press and turn to highlight the back suction time line Press the to enter next interface turn to adjust press to confirm or press to cancel the adjustment and return to...

Page 12: ...selection and return to previous menu Knob Knob Knob Knob Exit Key Calibration Pump should be calibrated when flow rate or dispense volume is beyond the tolerance Flow rate and dispensing volume can b...

Page 13: ...selection and return to previous menu Knob Knob Knob Knob Exit Key Calibration Pump should be calibrated when flow rate or dispense volume is beyond the tolerance Flow rate and dispensing volume can b...

Page 14: ...e working Thick wall tubing is preferred for longer service life Flow rate mode operation procedure Confirm the flow rate of the fluid which need to be pumped Press to enter interface to set pump head...

Page 15: ...e working Thick wall tubing is preferred for longer service life Flow rate mode operation procedure Confirm the flow rate of the fluid which need to be pumped Press to enter interface to set pump head...

Page 16: ...n the pump runs clockwise Close the pumps runs counter clockwise COM of external control input Terminal 1 Terminal 2 Terminal 3 Terminal 4 COM of external control input External control start stop inp...

Page 17: ...n the pump runs clockwise Close the pumps runs counter clockwise COM of external control input Terminal 1 Terminal 2 Terminal 3 Terminal 4 COM of external control input External control start stop inp...

Page 18: ...ocol Maintenance When the pump is idle we recommend you to release the tubing from pressure This helps to protect the tubing from unnecessary strain and prolongs its service life Keep rollers clean an...

Page 19: ...ocol Maintenance When the pump is idle we recommend you to release the tubing from pressure This helps to protect the tubing from unnecessary strain and prolongs its service life Keep rollers clean an...

Page 20: ...Longer Precision Pump Co Ltd ADD Building A Chuangye Center Baoding National High Tech Industrial Development Zone Baoding Hebei China 071051 TEL 86 312 3110087 3138553 FAX 86 312 3168553 E mail longe...