10
THIS MANUAL IS PROPRIETY OF
ECOWIND by LOMBARDINI
- ALL FORMS OF REPRODUCTION, PARTIAL OR OTHERWISE, IS STRICTLY PROHIBITED
G
B
GENERAL DESCRIPTION AND TECHNICAL DATA -
2
2.1
TECHNICAL CHARACTERISTICS
Table of technical data
Air-conditioning system
Model
350 “C” - AUS
Dimensions and
weight
Power unit
Con
denser
Split (diffuser)
Length
710 mm
560 mm
560 mm
Height
560 mm
360 mm
360 mm
Depth
290 mm
120 mm
140 mm
Weight
110 kg *
6 kg
10 kg
* Without support structure
350 “C” AUS
Fuel
Diesel for automotive use
(taken from the vehicle’s own tank for
models installed directly in vehicles)
Maximum fuel consumption
0,7 litre/ h
Cooling capacity
13.000 btu/h (3.800 W)
Coolant
R-134a
Quantity of coolant
min 1000 ÷ max 1200 gr. *
The amount of gas may vary according to pipe length see
Tab. 1 and Tab. 2
Optimum operating pressure:
Delivery pressure HP = 14 ÷ 17 bar - @ 30° C ext. temp.
Intake pressure LP = 1 ÷ 3 bar - @ 30° C ext. temp.
ATTENTION !!!
It is important to comply with the above quantities.
Non-observance of this recommendation could compromise the performance of the system
Onboard electrical power supply
12 V
24 V
Battery recharge capacity (alternator)
70 A - MAX
40 A - MAX
Evaporator airflow
600 m
3
/h - MAX
600 m
3
/h - MAX
Control system power supply
12 Vdc
24 Vdc
Summary of Contents for ECOWIND 350 C AUS