The LM410 is available in two elecric models: 230 V
3-phase 50 Hz and 400 V 3-phase 50 Hz.
The power cable to the log house moulder must be
at least 2.5 mm
2
/wire (1/8’’) and be max. 25 m (82
ft) long. If you have to use a longer cable, it must be
4 mm
2
/wire on the length that is more than 25 m.
If the log house moulder is stored in a cold room,
fluctuations in temperature will cause condensation
to accumulate in the motor and the junction box.
Check regularly that there is no water in the junction
box behind the control panel or in the enclosure of
the three-phase motor. The motor has a drain plug
on its underside.
The motor is started by a contactor. The power
that runs the electromagnet in the contactor, runs
through the two hold-to-run buttons and the safety
switch on the cutter-head hatch. All these three
have to work and be activated for the motor to
start.
Lubricate the industrial power inlet on the LM410
and the plug on the cable with silicone spray.
Lethal voltage. A faulty connection can lead to
death or serious injury.
Note that only qualified electricians are
authorized to open/access the electrical equipment.
Ensure that the power is disconnected before
opening the electrical system.
CIRCUIT DIAGRAM 400 V 3-PHASE
You can find the current circuit diagram for your
loh house moulder inside the junction box of your
machine.
CIRCUIT DIAGRAM 230 V 3-PHASE
You can find the current circuit diagram for your
loh house moulder inside the junction box of your
machine.
ELECTRICAL SYSTEM