Page. 7 of 45

 

1.3.

 

Code reader wiring diagram 

 

1.4.

 

C

onnection TERMINAL ► DS0

► D

M260 

Summary of Contents for DS03

Page 1: ...Rev 1 00 USER MANUAL...

Page 2: ...AT s r l No part of this document may be reproduced without the prior explicit permission of LOGOMAT s r l Page 2 of 45 A C E s r l Via A Costa n 61 40067 Rastignano Bologna Italia Tel 051 6260573 Fax...

Page 3: ...1 Setup 12 2 1 1 Head 1 13 2 1 1 1 1 Percentage 14 2 1 1 2 Selection Code 15 2 1 1 3 Outputs setting 17 2 2 Programming 18 2 2 1 Select Head 19 2 2 2 Programming Code 20 2 2 2 1 Keyboard 21 2 2 2 2 A...

Page 4: ...code reader this manual also pinpoints the essential aspects of the equipment DS03 is a compact code reader able to verify the read code An independent CPU for each reading channel makes for extremel...

Page 5: ...S03 L 5MT CVDMR260 DS03 10 POWER AND I O CABLE X DM260 COGNEX IN COMBINATION DS03 L 10MT CVDMR260 DS03 15 POWER AND I O CABLE X DM260 COGNEX IN COMBINATION DS03 L 15MT In combination with the VIRTUAL...

Page 6: ...dc With metallic isolation Absorption 10Watt Reading head power unit 12Vdc 5Vdc Inputs N 4 24VDC With optoinsulation Outputs N 4 24VDC With optoinsulation I O display By means of diodes on the front p...

Page 7: ...0 This document is a property of LOGOMAT s r l No part of this document may be reproduced without the prior explicit permission of LOGOMAT s r l Page 7 of 45 1 3 Code reader wiring diagram 1 4 Connect...

Page 8: ...all selections made 1 6 Rear panel elements CN1 12 pole connector for machine interfacing output CN2 10 pole connector for machine interfacing input PROG 10 pole connector for programming code reader...

Page 9: ...ng and positioning the reading heads PlLOGOMAT the reading head at a distance of about 70mm from the code reading position If the code is too glossy the reading head can be inclined by 15 For further...

Page 10: ...out display of the installed software version loading from EEPROM of the code values used during latest production display of the production menu Front panel signals Input LEDs 1 Head 1 reading phase...

Page 11: ...made and to enable the relevant menu Setup for optimising location of reading heads Programming displays the programming menu thus enabling and programming the reading heads Production monitors effect...

Page 12: ...this page select command Setup from the MAIN menu With this menu you can optimized the location of the reading heads To select one of the reading heads To confirm the selection made and to enable the...

Page 13: ...ermission of LOGOMAT s r l Page 13 of 45 2 1 1 Head 1 This page is accessed by selecting the Test 1 command from the SET UP menu To select one of the items shown To confirm the selection made and to e...

Page 14: ...LOGOMAT s r l Page 14 of 45 2 1 1 1 1 Percentage To access this page select command Percentage from the BAR OPT 1 menu This menu displays reading precision of the code as a percentage The higher it is...

Page 15: ...o access this page select command Selection Code from the SETUP1 menu This menu is used to set the code type which has to be recognized by the reading head SELECTION CODE Head 1 Interleaved 2 5 Tab Wr...

Page 16: ...No part of this document may be reproduced without the prior explicit permission of LOGOMAT s r l Page 16 of 45 To display the code type to be recognized To confirm the set code returning to the previ...

Page 17: ...etting from the SETUP 1 menu This menu is used to set the time of the head reading OK signal If the reading time is set to 0 msec the head reading OK signal lasts till the reading phase of the next he...

Page 18: ...o access this page select command Programming from the MAIN menu This menu is used for enabling and programming the reading heads To select one of the items shown To confirm the selection made and to...

Page 19: ...select the reading head to be enabled or disabled To change the enabling status ON OFF of the reading head Return to previous menu maintaining the set status By pressing the Write key the status of t...

Page 20: ...hout the prior explicit permission of LOGOMAT s r l Page 20 of 45 2 2 2 Programming Code To access this page select commad Programming Code from the PROGRAMMING menu To select one of the items shown T...

Page 21: ...e SCROLL and SHIFT keyes Consente di visualizzare singolarmente il codice di ogni testa di lettura oppure in caso di testa non collegata lo stato OFF Abilita i tasti SCROLL e SHIFT Si torna al men pre...

Page 22: ...access this page select command Autoset from the PROGRAM menu By positioning a code in front of the reading head this menu enables you to automatically acquire the read code To individually display th...

Page 23: ...mission of LOGOMAT s r l Page 23 of 45 2 2 2 2 1 Code Acquired To read the read code To save the last code read displaying the following menu Code Acquired Correct Esc Yes Enter No PHARMACODE Code Acq...

Page 24: ...menu To select one of the items shown To confirm the selection made and to enable the relevant menu Return to previous menu Memory read for loading as a current code to be verified a format from the n...

Page 25: ...Memory read To access this page select command Memory read from the MEMORY menu It is used for loading as a current code to be verified a format from the non volatile EEPROM memory To select the forma...

Page 26: ...thout the prior explicit permission of LOGOMAT s r l Page 26 of 45 Enter Fig A Fig B By pressing Tab the following settings can be displayed SHIFT CONSECUTIVE ERRORS CODE TYPE TO BE READ BY THE HEAD W...

Page 27: ...emory write To access this page select command Memory write from the MEMORY menu It is used for saving the current code to be verified in a format from the non volatile EEPROM memory To select the for...

Page 28: ...thout the prior explicit permission of LOGOMAT s r l Page 28 of 45 Enter Fig D Fig E By pressing Tab the following settings can be displayed SHIFT CONSECUTIVE ERRORS CODE TYPE TO BE READ BY THE HEAD W...

Page 29: ...45 2 2 2 3 3 Memory delete To access this page select command Memory delete from the MEMORY menu It is used for deleting a format from the non volatile EEPROM memory To select the format To enable the...

Page 30: ...thout the prior explicit permission of LOGOMAT s r l Page 30 of 45 Enter Fig G Fig H By pressing Tab the following settings can be displayed SHIFT CONSECUTIVE ERRORS CODE TYPE TO BE READ BY THE HEAD W...

Page 31: ...ssion of LOGOMAT s r l Page 31 of 45 2 2 3 Current Format To access this page select command Current format from the PROGRAMMING menu Return to previous menu By pressing Tab the following settings can...

Page 32: ...eading head Return to previous menu 2 2 5 Shift Register To access this page select command Shift Register from the PROGRAMMING menu This menu is used to program the shift steps The OK signal is shift...

Page 33: ...ift1 X from the Shift Register menu To select the step number max 32 To select the step number max 32 To confirm the selection made Return to previous menu 2 2 6 Consecutive To access this page select...

Page 34: ...mand Errors 1 0 from the Consecutive menu This menu is used to set the number of consecutive errors max 10 After this number of consecutive errors the machine stops If the set number is 0 zero the che...

Page 35: ...selection made and to enable the relevant menu Return to previous menu 2 3 1 Single head To access this page select command Single head from the PRODUCTION menu This menu shows individually the last...

Page 36: ...e prior explicit permission of LOGOMAT s r l Page 36 of 45 2 3 2 Multiple heads To access this page select command Multiple heads from the PRODUCTION menu This menu shows at the same time the last cod...

Page 37: ...ed without the prior explicit permission of LOGOMAT s r l Page 37 of 45 2 3 3 Reset counters To access this page select command Reset counters from the PRODUCTION menu It enables you to reset the coun...

Page 38: ...AT s r l Page 38 of 45 2 4 Language To access this page select command Language from the MAIN menu This menu allows the setting of the language to be used in the menu To select one of the items shown...

Page 39: ...oad Bar optimization Tab Enter Select Setup Select Head1 BAR OPT 1 Overflow Percentage Tab Enter Select Bar optimization 2 Select Percentage Locate the code to be read e g a leaflet at a distance of a...

Page 40: ...45 2 5 2 Enabling reading head no 1 1 MAIN Setup Programming Production PROGRAMMING Select head Programming code Tab Enter SELECT HEAD Head 1 On Head 2 Off Tab Write Select Programming Select Select...

Page 41: ...ode Tab Enter PROGRAM Keyboard Autoset Memory The displayed code is the code that the reading head sees if reading is correct press the ESC key By pressing this key you enter the ACQUIRED menu where t...

Page 42: ...s document may be reproduced without the prior explicit permission of LOGOMAT s r l Page 42 of 45 2 5 4 Start of the production cycle PRODUCTION Single head Multiple head Reset count 1 MAIN Setup Prog...

Page 43: ...r l No part of this document may be reproduced without the prior explicit permission of LOGOMAT s r l Page 43 of 45 2 5 5 Mounting Mounting the DM 260 at a slight angle 15 can reduce reflections and...

Page 44: ...Lens Short Range Focused to 105 mm The following tables show the Field of View FoV widths of the 6 2 mm lens focused to 105 mm at various distances Distances in mm 2D min code 2D min code 40 4 MIL 2...

Page 45: ...widths of the 6 2 mm lens focused to 190 mm at various distances 131 5000 Distances in mm 2D min code 1D min code 150 12 MIL 6 MIL 190 15 MIL 10 MIL 225 18 MIL 10 MIL 375 30 MIL 15 MIL 500 35 MIL 20 M...

Reviews: