1.2.
Central unit technical features DS03
The reading heads are connected to the equipment by RJ45 connectors.
Connection to the machine is via 10- and 12-pole industrial connectors
Specifications:
Mechanical
Dimension
96x96x100mm
Housing
Shielded
Electrical
Power supply
24Vdc
With metallic isolation
Absorption
10Watt
Reading head power unit
12Vdc/5Vdc
Inputs
N° 4 24VDC
With optoinsulation
Outputs
N° 4 24VDC
With optoinsulation
I/O display
By means of diodes on the front panel
InterfLOGOMAT with Host
RS232 C
Optical
Reading distance
Laser
Static or moving code reading Da 45 a 70mm
Code length
Max. 50mm
Number of bars
Max. 12
Miscellaneous
Display
16 digits x 4 lines alphanumeric display
Check speed
Max. 100m/min
Programming
Self-learning
Code entering through keyboard
Code entering from memory
Codes that can be
checked
DM260
Pharma Code
EAN13
–
EANB - EAN128
ITF 2/5 Check - ITF 2/5
UPCA - UPCE
Code39 Check - Code39
–
Code128
UPCE