16
5.0 There must be a current supply...
5.4 Battery charging
If instructions accompany the battery / charger, these are to be
followed.
The Soneil charger is set for charging of both semi-track, tubular cell
•
and maintenance free batteries.
NOTE!
•
If another charger is used, the charging voltage has to be set
correctly for the charging of semi-track, tubular cell or maintenance
free batteries.
Charging simultaneously with truck operation is not recommended.
•
Longest battery life is achieved when charging when battery is:
•
80% discharged (semi-trak and tubular cell)
70% discharged (maintenance-free).
Charging of the batteries: Max. once per day
•
Semi-trak and tubular cell batteries are to be filled with distilled water after max.
•
14 cycles. 1 charging = 1 cycle.
During the charging, the temperature in the battery is not allowed to
•
exceed 50° C.
Charging
1. Connect charger to battery (24 volt)
(If the charger is built in, the charger is connected)
2. Connect the charger to the mains (230 V/115 V).
NOTE!
The voltage switch has to be set correctly, as wrong settings can damage
the charger.
(red lamp shines when built-in charger)
3. Charging with built-in charger
- Charging starts, red lamp (2) is on.
The charger disconnects the control circuit.
Note!
All the functions of the truck are disconnected.
- If the charger remains connected, the charging will stop after finished course
of charging.
- When fully charged, the green lamp is on (2)