18
3IKRINGER
&USES
&USIBLES
3ICHERUNGEN
5.0 There must be a current supply...
5.5 Fuses - replacement
There are 4 fuses in the electrical circuit, located
behind the plate with this pictogram.
A) 80 Amp fuse for driving motor
B) 50 Amp fuse for lifting motor
C) 10 Amp fuse (Soneil charger)
D) 5 Amp fuse in the control current circuit
Replacement:
The old fuse is to be removed and replaced
by a new one of the same size.
Do not insert a larger fuse; the fuse acts as a protector for the pump motor.
Find out why fuses blow!
5.6 Wiring connections
Many operational disturbances are caused by bad connections in the
electrical circuit. Make sure that the connections are in order.
Check connections regularly for damage at insulating caps or bad connections at
plugs etc. Verdigris must be removed from cable plugs. Keep all screw/nut
connections tight.