Connector X1: 4 pin PWR connector overview
Pin
Name
Description
1
SUPP
Power supply, positive (+) connection
2
DI5/IGN
Digital input 5 / Ignition input (Shared with X3)
3
SUPP
Power supply, positive (+) connection
4
PGND
Power Ground
Connector X2: 12 pin COM connector overview
Pin
Name
Description
1
1Wire
1-Wire bus
2
SGND
Signal Ground
3
CAN-H
CAN-bus H-signal
4
Voice
External voice
5
RS485+
RS485 non-inverting signal
6
RS485-
RS485 inverting signal
7
1W-LED
1-Wire ID-Button LED
8
SGND
Signal Ground
9
CAN-L
CAN-bus L-signal
10
SGND
Signal Ground
11
SGND
Signal Ground
12
DC-Out
+3.3V/150mA DC-Out for external equipment. (Shared with X4)
Connector X3: 16 pin I/O connector overview
Pin
Name
Description
1
DOUT 1
Digital output 1
2
DOUT 3
Digital output 3
3
DIN 1
Digital input 1
4
SGND
Signal Ground
5
DIN 3
Digital input 3
6
DIN 5/IGN Digital input 5 / Ignition input (Shared with X1)
7
AIN 1
Analog input 1
8
AIN 2
Analog input 2
9
DOUT 2
Digital output 2
10
DOUT 4
Digital output 4
11
DIN 2
Digital input 2
12
SGND
Signal Ground
13
DIN 4
Digital input 4
14
SGND
Signal Ground
15
AGND
Analog Ground
16
AGND
Analog Ground