RTCU LX5 eco Technical Manual V1.00
Advanced Industrial M2M/IoT Gateway
Logic IO ApS.
Ph: (+45) 7625 0210
Holmboes Allé 14
Fax: (+45) 7625 0211
8700 Horsens
Page 13 of 33
Email: [email protected]
Denmark
Digital Inputs / Ignition Input
The digital inputs are all low-pass filtered and transient protected. To activate the inputs, connect a
positive voltage between the input and the GND connector.
Please note:
The DIN 1/IGN input is unique as it also functions as the ignition input. If the ignition
input is activated with a logically high or low (Wait For Event mode only), it will wake up the unit
when the RTCU is in low power mode. A power apply will also wakeup the unit, if it is in power-
down mode or WaitForEvent mode with power Apply and/or ignition selected for wakeup.
The power management allows the possibility to configure a wakeup on one or more digital inputs
with individually configured falling- or rising edge detection. Please consult the RTCU IDE
documentation for additional information.
16 pin I/O connector overview.
Pin
Name
Description
2
DIN 1/IGN Digital input 1 / Ignition input.
3
DIN 2
Digital input 2
4
DIN 3
Digital input 3
5
GND
Signal Ground
Specification for each digital input:
Min. Typ. Max.
Unit
Logic "High"
8
12
40
VDC Protected against transients and
low-pass filtered
Logic "Low"
-5
-
3
VDC
Bandwidth
-
7
-
kHz
Input impedance
-
14
-
kΩ