background image

10 

SYSTEM SETUP 

 

1  

Install the LS6100 units as described in HARDWARE INSTALLATION section. 

 
2  

Setup optional parameters on LS6100 if necessary (for example, RS232 baud rate and 
beeper pitch). 

 
3  

Setup the LS6100 station address used for quick identification of the station. 

 
4  

Setup LS6100 IP address, subnet mask and port number to the required values.  Check 
with system administrator for proper settings.  Note that the IP address must match the 
IP group of the host server and the TCP port address must match the port number used 
by the application software. 

 
5. 

Save parameters and exit setup. 

 
6  

Verify  that  the  values  on  the  boot  up  screen  shows  the  correct  set  up  values.    If  not, 
repeat step 2 to 5 to correct the settings. 

 

The setup for one LS6100 is now completed. Repeat as necessary for each LS6100 in 
the system, ensuring a unique IP address for each LS6100.  Always verify the setting on 
the boot up screen. 

 
8. 

Check  the  host  server  IP  address  to  make  sure 

that  it’s  in  the  same  IP  group  as  the 

LS6100 units.  Setup the server IP address if necessary. 

 
9. 

Setup the application software if necessary, including TCP port number setting. 

 
10.  Run the application software or a test program to verify functions of the system. 
 

Summary of Contents for LS6100

Page 1: ...Kitchen Display Station Controller with Ethernet Interface USER MANUAL AND INSTALLATION GUIDE LS6100...

Page 2: ...is in conformity with the protection requirements of EU Council Directive 89 336 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility Logic Controls cann...

Page 3: ...ducts plugged into the wall outlet does not exceed the fuse rating 7 We recommend all servicing done on this product be done by qualified service personnel Aside from upgrades or swapping out the comp...

Page 4: ...OF CONTENTS FEATURES 1 PRODUCT DESCRIPTION 3 CONNECTOR PINOUTS 5 HARDWARE INSTALLATION 6 LS6100 SETUP AND SELF DIAGNOSTIC TESTS 7 SYSTEM SETUP 10 TROUBLE SHOOTING 11 SOFTWARE DEVELOPMENT 13 SPECIFICA...

Page 5: ...ntinuously showing connection status of Ethernet and keyboard Touch screen support serial interface Status line display for showing status messages help items alerts or on screen touch function keys w...

Page 6: ...ons of the command set Source code of mini applications to answer all how to write questions Free phone and e mail technical support Self diagnostic Automatic power on and diagnostic tests for Interna...

Page 7: ...eper tone can be adjusted from the LS6100 Setup screen Keyboard An RJ 11 to PS2 adapter will connect the LS6100 to a standard PC keyboard Other keyboard wedge interface input devices such as Bumpbars...

Page 8: ...utput is connected to the LS6100 with locking connectors Nominal Voltage 100 240 V AC Voltage Variation 90 265 V AC Frequency 47 63 Hz 1 Custom driver code in firmware is required for supporting diffe...

Page 9: ...RS 232 interface 8 pin RJ45 connector EIA 561 pin out 1 DSR 2 DCD 3 DTR 4 GND 5 RXD 6 TXD 7 CTS 8 RTS Keyboard interface 6 pin RJ 11 connector 1 CLK 2 DATA 3 No connection 4 Signal GND 5 5 V DC 6 No c...

Page 10: ...with the mounting brackets have the capacity to support 4 3 kg 9 5 lb This weight is determined by adding a safety margin weight to the weight of the unit Wall anchors with specified weight capacity...

Page 11: ...line ON Ethernet icon ON Keyboard icon ON Font code page tcp437 Space ESC Ctrl F10 0 1 F1 Help Select Item Change Value F9 Load Defaults Esc Exit Select Menu Enter Accept Value F10 Save and Exit Ther...

Page 12: ...number Select bit number option 7 bits or 8 bits Flow Control Select flow control option none or hardware Device Driver Select or disable integrated device driver for the COM port DIAGNOSTIC menu 1 VG...

Page 13: ...the LS6100 and host server Check the IP settings and Ethernet cable connections Note that the LS6100 and host server must be in the same IP group EXIT menu 1 Exit and Save Save the changes made and e...

Page 14: ...e port number used by the application software 5 Save parameters and exit setup 6 Verify that the values on the boot up screen shows the correct set up values If not repeat step 2 to 5 to correct the...

Page 15: ...the LS6100 IP address is correct and unique 3 If the host IP address is not shown in the status screen check Ethernet cable connections 4 Check the Ethernet cable connections at the LS6100 and at the...

Page 16: ...lace the cable or keyboard and test again 4 Test with known good keyboard and cable If it fails replace the LS6100 Attached RS 232 device is not working 1 Check that the device and LS6100 have power 2...

Page 17: ...100 with minimal changes For further assistance please contact support logiccontrols com Logic Controls recognizes that a highly reliable video network with zero interruption is desirable for all appl...

Page 18: ...ing relative humidity 5 to 80 non condensing Storage temperature 0 C to 60 C Storage relative humidity 5 to 85 non condensing INTEFACES Ethernet 10 100 BaseT Video port Standard VGA Bumpbar keyboard P...