 SPACE 2000 (T and M versions)          OPERATION MANUAL

 

 

26 

 

MACHINE PARAMETER DESCRIPTION  

 

P00 =  Selection of type of application and number of axes 

enabled (“n”).

 

The coherent values for this parameter are:  

0”n” / 

 

1”n”

 

With  parameter  P00,  the  SPACE  2000  defines  whether  the  application  is  for  a 
lathe (P00= 0”n”) or a milling machine or boring machine (P00= 1”n”). 
The value “n” varies from 1 to 4 axes for the Space 2000, and from 1 to 3 axes for 
the Space 2000 “ RIF”. 
Whenever any of these values are selected, the SPACE 2000 automatically writes 
the  standard  values  indicated  in  the  machine  parameter  table  in  the  following 
parameters and enables the nu

mber of axes that corresponds to the  value “n”.  

(see the M.P. table) 
 

P01 = Switching to Display OFF condition. 

The range of coherent values runs from: 

0000 

to 

9999

 

When left in out-of-use condition (without making any selections on the keyboard 
or  axis  shifting)  and  after  the  time  (expressed  in  seconds)  set  using  parameter 
P01,  the  SPACE  2000  automatically  assumes  display  OFF  condition  (display 
switching  off  and  enabling  of  the  moving  decimal  point  for  all  the  axes  enabled, 
digit by digit). 
The value of parameter 

P01 = 0000

 defines the disabling of the function. 

Display OFF condition can be changed by making any selection with the Enter key 
or by simply shifting an axis. 
 

P02 = Selection of message language (only for SPACE PRO version) 

The range of coherent values varies as prescribed in the table below: 
 

ITALIAN 

 

FRENCH 

 

SPANISH 

 

ENGLISH 

 

GERMAN 

In the standard version, only the “0” value can be entered because the messages 
that appear on the "X"-axis are universally understandable symbols. 

 
P03 = RS 232 serial line enabling (Optional) 

The serial line is an optional that requires hardware variations in the main board. 
The values that can be set for this parameter are as follows:  
 

Serial line not enabled  

 

Serial line enabled in 

operation mode “1” 

 

Serial line enabled in operation mode “2” 

Contact LOGAN Technical Service for further details. 

 

 

P04 = RS 232 serial line character format 

This  defines  the  format  of  the  character  to  be  used  for  adaptation  to  the 
peripherals to which the serial line is connected (Personal Computer, Printers)  
The  values  that  can  be  programmed  for  this  parameter  are  shown  in  the  table 
below. 

Summary of Contents for SPACE 2000

Page 1: ...0040 VOLVERA TORINO ITALY TEL 0039 011 990 60 60 4 lines with a r FAX 0039 011 985 90 73 www logansrl it e mail info logansrl it LOGAN S r l Strada Panealba 2 10040 VOLVERA TORINO ITALY TEL 0039 011 990 60 60 4 linee r a FAX 0039 011 985 90 73 www logansrl it e mail info logansrl it ...

Page 2: ...ersions OPERATION MANUAL 1 Operation Manual Code 19 06 3030 01 LOGAN S r l Str da Panealba 2 10040 VOLVERA TORINO ITALY TEL 0039 011 990 60 60 4 lines with a r FAX 0039 011 985 90 73 www logansrl it e mail info logansrl it ...

Page 3: ...5 Absolute Relative Switching 16 Absolute zero memorisation piece zero F1 17 Absolute zero restoration piece zero F2 18 Average point calculation F3 19 Automatic relative pre set F4 20 Millimeter inch conversion F5 22 Radius diameter switching only T version F7 23 Longitudinal axes summation enabling only T version F8 24 MACHINE PARAMETER PROGRAMMING M P 25 MACHINE PARAMETER TABLE 26 MACHINE PARAM...

Page 4: ...ng procedures described in this manual the meanings of the following terms must be absolutely clear See the figure below SPACE 2000 M version SPACE 2000 T version PIECE ZERO ABS ABSOLUTE DIM INCR RELATIVE DIM MACHINE ZERO 0 REF Z Z1 AXIS X AXIS INCR RELATIVE DIM ABS ABSOLUTE DIM MACHINE ZERO 0 REF PIECE ZERO X AXIS Y AXIS ...

Page 5: ...selection key Absolute to incremental dimension and vice versa switching key Power supply connected signal Signalling of absolute zero dimension Signalling of dimension expressed in inches Signalling of position display Signalling of diametral dimension only for X axis X Z Z1 0 9 CL F TOOL ABS INCR Ent ABS INCH POS DIA PWR t 0 X ABS INCR Z TOOL Z1 7 8 9 4 5 6 1 2 3 0 F CL Ent logan 12345 67 X ABS ...

Page 6: ...bling key Origin enabled selection key Absolute to incremental dimension and vice versa switching key Power supply connected signal Signalling of absolute zero dimension Signalling of dimension expressed in inches Signalling of position display X Y Z 0 9 CL F ORG ABS INCR Ent ABS INCH POS PWR o 0 X ABS INCR Y ORG Z 7 8 9 4 5 6 1 2 3 0 F CL Ent logan 12345 67 X ABS INCH POS PWR 12345 67 Y 12345 67 ...

Page 7: ...enabling key Absolute to incremental dimension and vice versa switching key Power supply connected signal Signalling of absolute zero dimension Signalling of dimension expressed in inches Signalling of position display X ABS INCR Y Z 7 8 9 4 5 6 1 2 3 0 F CL Ent logan 12345 67 X ABS INCH POS PWR 12345 67 Y 12345 67 ABS INCH POS Z ABS INCH POS 12345 67 ABS INCH POS W W ABS INCR 0 9 CL F Ent ABS INC...

Page 8: ...The title is followed by a brief explanation of the function performed by the procedure that provides immediate knowledge of how it works and the consequences of its use Whenever necessary its relationship with other procedures described in other modules is explained Indications on the appropriateness of the function are provided that make perfectly clear how why and when the respective function c...

Page 9: ...000 responds to the operator s manoeuvres indicated in the first column are shown in the second column Any particular conditions differences or variations from normal use are described under IF NECESSARY in the third column which explains how to avoid or remedy error conditions and resume normal use Each elementary step is separated from the previous step and the following step by a division line ...

Page 10: ...e check the PWR LED remains lit up steadily and all the display conditions that were valid before switching off are re proposed with flashing LED The flashing of the dimensions means that these dimensions can be considered valid provided that the axes have not been shifted with the SPACE 2000 power supply switched off the internal memory has not been set to zero the ZERO POWER RAM offers a minimum...

Page 11: ... set in position display conditions POS LEDs ON Select the key M version T version The orG or tool message appears on the X axis display to indicate the command executed and the waiting for the numerical value of origin tool All the LEDs switch off except PWR The origin tool display is switched off awaiting modifications In order to quit this selection and return to the position display press the ...

Page 12: ...g to be performed refer to Simultaneous zero setting makes setting up the SPACE 2000 for work quick and easy Necessary conditions the SPACE 2000 must be set in position display conditions POS LEDs ON Select the key The ABS message appears on the X axis display to indicate the selection of the command All the LEDs switch off In order to quit this selection and return to the position display press t...

Page 13: ... to be set must be expressed in millimeters with the format selected from the machine parameters The display of the axis selected will gradually show the figures entered followed by the flashing cursor During this setting the selection of the axis can still be changed because the SPACE 2000 assigns the figures entered to the new axis up to this moment In order to cancel one or more figures entered...

Page 14: ...etween the current axis position and the RELATIVE ZERO to be established The number to be set must be expressed in millimeters with the format selected from among those of the machine parameters The display of the axis selected will gradually show the figures entered followed by the flashing cursor During this setting the selection of the axis can still be changed because the SPACE 2000 assigns th...

Page 15: ...istake press the correct selection key In order to quit this selection and return to the position display press the key In order to enable the function select the key The display shows the absolute dimension of the axis selected if the relative dimension was shown previously and vice versa The ABS LED either lights up or if it was previously lit up switches off All the displays of the axes are re ...

Page 16: ...be enabled All the LEDs except PWR and the displays of the other axes are switched off The indication of the origin tool remains enabled In order to quit this selection and return to the position display press the key In order to enable the function selected press The X axis display will show the SEL ASSE message in order to inform the operator to select the axis for the execution of the function ...

Page 17: ... of the origin tool remains enabled In order to quit this selection and return to the position display press the key In order to enable the function selected press The X axis display will show the SEL ASSE message in order to inform the operator to select the axis for the execution of the function selected In order to quit this selection and return to the position display press the key Select the ...

Page 18: ...ed All the LEDs except PWR and the displays of the other axes are switched off The indication of the origin tool remains enabled In order to quit this selection and return to the position display press the key In order to enable the function selected press The X axis display will show the SEL ASSE message in order to inform the operator to select the axis for the execution of the function selected...

Page 19: ...nd return to the position display press the key In order to enable the function selected press The X axis display will show the SEL ASSE message in order to inform the operator to select the axis for the execution of the function selected In order to quit this selection and return to the position display press the key Select the axis involved by pressing any of the keys T version M version The dis...

Page 20: ...ows pag 20 6 Reach point D by bringing the display to zero and hypothesise a positioning error of 0 02 mm 7 With the axis in point D in order to re present the same step defined above proceed as follows pag 20 8 As may be seen in point 7 the dimension recalled has considered the positioning error and now point E can be reached 9 Recall the absolute dimension in order to enable return to point A an...

Page 21: ...ns POS LEDs on Select the function by pressing the following keys The F5 message appears on the X axis display to indicate the choice of the function to be enabled All the LEDs except PWR and the displays of the other axes are switched off The indication of the origin tool remains enabled In order to quit this selection and return to the position display press the key In order to enable the functi...

Page 22: ...on the X axis display to indicate the choice of the function to be enabled All the LEDs except PWR and the displays of the other axes are switched off The indication of the origin tool remains enabled In order to quit this selection and return to the position display press the key In order to enable the function selected press The DIA ON message appears on the X axis if the radius display conditio...

Page 23: ...ger coaxial with the carriage s longitudinal axis Necessary conditions a SPACE 2000 3 axes T version must be present the SPACE 2000 must be set in position display conditions POS LEDs ON Select the function by pressing the following keys The F8 message appears on the X axis display to indicate the choice of the function to be enabled All the LEDs except PWR and the displays of the other axes are s...

Page 24: ... the following key pressed during switch on until the first parameter appears The first parameter P00 appears on the X axis display together with its value All the LEDs except PWR and the displays of the other axes are switched off The indication of the origin tool is also disabled Each time the following key is pressed the SPACE 2000 runs a coherence check on the parameter If the parameter is con...

Page 25: ...pment in its entirety and are distinguished by the fact that their numerical value begins with a zero M P DESCRIPTION VALUES LATHE MILLER SPEC P00 Selection of type of application and number of axes enabled n 0 n 1 n P01 Switching to Display OFF condition 0000 0000 P02 Selection of message language only for SPACE PRO version 0 0 P03 RS 232 serial line enabling Optional 0 0 P04 Serial line characte...

Page 26: ... n of parameter P00 1 1 P21 Counting direction 0 0 P22 Display format 4 2 5 2 P23 Transducer pulse value integer part 0010 0001 P24 Transducer pulse value decimal part 0000 0000 P25 Zero achieved output enabling Optional 0 0 Z1 AXIS T version Z AXIS M version P30 Enabling depends on the value n of parameter P00 1 1 P31 Counting direction 0 0 P32 Display format 4 2 5 2 P33 Transducer pulse value in...

Page 27: ...g off and enabling of the moving decimal point for all the axes enabled digit by digit The value of parameter P01 0000 defines the disabling of the function Display OFF condition can be changed by making any selection with the Enter key or by simply shifting an axis P02 Selection of message language only for SPACE PRO version The range of coherent values varies as prescribed in the table below 0 I...

Page 28: ...values that can be set for this parameter are as follows 0 38400 Baud 1 19200 Baud 2 9600 Baud 3 4800 Baud 4 2400 Baud 5 1200 Baud 6 600 Baud P06 Input enabling for the measurement tracer point The measurement tracer point input is an optional that requires hardware variations in the main board The values that can be programmed for this parameter are as follows 0 Input for tracer point disabled 1 ...

Page 29: ...maintained for the period of time set with parameter P09 1 The zero achieved signal is enabled by the passage of the display over the 0 value and maintained until it shifts positively or negatively from the 0 point by the space defined with parameter P09 P09 Numerical value that defines P08 mode The value that can be programmed runs from 0000 to 9999 With P08 0 Each P09 unit corresponds to 20 ms W...

Page 30: ...of the decimal point integer and the second number indicates the digits to the right decimal that must be shown on the display All combinations are possible except values in which the sum of the two numbers exceeds 7 the maximum number of digits values in which the first number is equal to 0 the minimum number of the integer digit 1 Example P12 5 2 X axis display X 00000 00 P22 4 3 Y axis display ...

Page 31: ... 2 The smallest decimal figure is the hundredth of a millimeter P13 0000 0000 P14 Expresses the pulse value in hundredths of a millimeter Expresses the pulse value in tenths of hundredths of a millimeter 0001 0000 With centesimal transductions set Each pulse corresponds to 0 01 mm 0000 5000 With 5 thousandth transductions set Each pulse corresponds to 0 005 mm 0000 1000 With thousandth transductio...

Page 32: ... to make linear correction for any errors that might be present in the tool machine axis P15 P25 P35 P45 Zero achieved output enabling Optional The zero achieved output is an optional that requires hardware variations in the main board The range of coherent values runs from 0 to 7 With the 0 value the zero achieved output is disabled values from 1 to 7 identify the enabling and the corresponding o...

Page 33: ...tch on has been quit and waits for the user to enter the numerical value coherent with the type of product application 5 Inch On Inch OFF These messages appear during the enabling or disabling of the F5 function for the indication of the selection being made 6 DIA On DIA OFF These messages appear during the enabling or disabling of the F7 function for the indication of the selection being made 7 D...

Page 34: ... parameter value that is incoherent with the system In this case the message is shown for around 2 seconds and then the incoherent parameter reappears for correction by the user see the description provided for the M P 2 Fun inc This message appears during the entry of a function value that is incoherent with the system The control test is conducted when the Enter key is pressed after the entry of...

Page 35: ...unction reappears for the correction of the value by the user 5 ASSE Out This message appears when the numerical value of an axis exceeds the maximum stroke that can be managed according to the display format set with parameters P12 P22 P32 In any case the internal counters of the SPACE 2000 do not lose the position and by inverting the movement and returning within the range of values that can be...

Page 36: ...PERATION MANUAL 35 INSTRUCTIONS FOR REPAIR Contact Technical Assistance Service LOGAN s r l Str da PANEALBA 2 10040 VOLVERA TO ITALY Tel 39 011 990 60 60 4 lines with a r Fax 39 011 985 90 73 www logansrl it e mail info logansrl it ...

Page 37: ...83 392 91 368 93 44 93 68 and complies with the requirements of the standard specified The Legal Representative Volvera __________ Roberto Palermi Director logan s r l S da Panealba 2 10040 VOLVERA TORINO ITALY Tel 011 990 60 60 4 lines with a r Fax 011 985 90 73 www logansrl it e mail info logansrl it cap soc 41 316 00 c c i a a TO 504720 reg soc trib TO 229 76 partita iva e cod fiscale 013479300...

Page 38: ...ons OPERATION MANUAL 37 SPACE 2000 VERSION T M SPEC OPTIONS SERIAL LINE ZERO ACHIEVED BUFFER BATTERY SERIAL NUMBER SOFTWARE VERSION POWER SUPPLY 24 110 220 TRANSDUCER POWER SUPPLY 5 12 AXES NO 1 2 3 4 INSPECTION DATE INSPECTOR ...

Page 39: ...SPACE 2000 T and M versions OPERATION MANUAL 38 NOTES ...

Reviews: