SPACE 2000 (T and M versions) OPERATION MANUAL
14
Absolute - Relative Switching
This function is used to switch from the absolute dimension display to the relative
dimension display and vice-versa, and is usually used only to return to the
absolute dimensions because they regard the PIECE ZERO; the opposite
passage is made automatically for many functions.
The SPACE 2000 shows the absolute dimension display with the ABS LED ON.
The display of the relative dimensions refers to the zero set by the latest zero-
setting or the relative pre-selection.
Necessary conditions:
the SPACE 2000 must be set in position display conditions ("POS" LEDs on)
Select
the
axis
involved
by
pressing any of the keys:
T version
M version
A flashing
"0"
appears on the
display of the axis selected.
The display of the other axes is
disabled.
All the LEDs switch off.
If the wrong axis is selected by
mistake,
press
the
correct
selection key.
In order to quit this selection and
return to the position display, press
the key :
In order to enable the function,
select the key :
The display shows the absolute
dimension of the axis selected if
the relative dimension was shown
previously and vice-versa.
The ABS LED either lights up or if
it was previously lit up, switches
off.
All the displays of the axes are re-
enabled and the SPACE 2000
returns to normal position display
status.
Switching to the absolute dimensions takes place automatically in the
following cases:
after the simultaneous absolute zero-setting command.
Pag. 13
after the absolute pre-selection command.
Pag. 14
after the absolute zero memorisation function (“
F1
”).
Pag. 17
after the absolute zero restoration function (“
F2
”).
Pag. 18
Switching to the relative dimensions takes place automatically in the
following cases:
after the relative pre-selection or zero-setting command.
Pag. 15
after the average point calculation function (“
F3
”).
Pag. 19
after the automatic preset function (“
F4
”).
Pag. 20
F
X
Z
Z
1
X
Y
Z
W
X
Z
Z
1
X
Y
Z
W
ABS
INCR