To the Dealer:
In order to ensure compatibility / performance of the Loftness attachment and the customer’s power unit, it is IMPERATIVE
that this Pre-Delivery Inspection (“PDI”) be completed using the customer’s actual power unit.
PRE-DELIVERY INSPECTION
Dealer: By initialing each line I understand and promise that I have completed the following:
____ Verified the attachment is set up properly for customers power unit. (check model code with manual)
____ Greased all grease zerks till grease purges out of bearing.
____ Removed all shipping brackets.
____Adjusted push bar out of shipping position. (if equipped) (full forward position recommended)
____ Installed head on customer’s unit that will be running the attachment and set hydraulic flow per power unit
manufacturer owner’s manual for preferred flow.
____ Recorded the Serial Number / Make / Model of the power unit.
Power unit. S/N _____________________ Make ________________ Model ___________________________
____ Recorded the Serial Number and Model of the Loftness attachment. S/N _____________ Model_____________
____ Verified power unit manufacturer outlined Auxiliary coupler orientation for pressure, return & case drain line.
____ Verified/recorded rotor RPM at full throttle per model & chart in Loftness owner’s manual. RPM _____________
____ Performed an Auxiliary system pressure stall check on the power unit only and verified that max pressure rating is
achieved per power unit manufacturer specifications. Recorded pressure observed _______________ PSI
PDI completed by: ________________________________ Print
________________________________ Signed/Date
Contact Loftness factory if any of the tests are not within power unit or Loftness specifications.
DELIVERY
____ Showed customer all grease zerks.
____ Showed customer adjustable push bar options. (if equipped)
____ Showed customer how to properly engage hydraulics to operate attachment.
____ Reviewed owner’s manual, all on-product warnings and instructions, and safe operation with customer.
____ Assisted customer with completing / submitting Warranty Registration Form to Loftness by one of the below options.
Dealer also needs to submit a copy of this completed PDI to Loftness and maintain the copy in owner’s manual for unit.
Mail to:
Loftness Specialized Equipment
Delivered to Customer by: ___________________________________Print
PO Box 337
Hector, MN 55342
___________________________________Signed/Date
Email to: Cheryl Schmalz
LOFTNESS COPY
Summary of Contents for 60BA4
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ...2 Bad Ax Disc Mulcher OM...
Page 26: ...16 Bad Ax Disc Mulcher OM...
Page 36: ...26 Bad Ax Disc Mulcher OM...
Page 37: ...27 Bad Ax Disc Mulcher OM PARTS IDENTIFICATION Parts Identification...
Page 38: ...28 Bad Ax Disc Mulcher OM Parts Identification...
Page 54: ...44 Bad Ax Disc Mulcher OM Parts Identification...
Page 57: ...47 Bad Ax Disc Mulcher OM Appendix Torque Specifications Inches Hardware and Lock Nuts...
Page 58: ...48 Bad Ax Disc Mulcher OM Torque Specifications Cont d Metric Hardware and Lock Nuts Appendix...
Page 59: ......