5.1 Measurement reset
Press the
(ON)
key to activate controls and to switch on the display lighting. The display lighting switches off 30 seconds
after the last command given (adjustable default time – see “BkLight Time”).
Measurement reset is performed in the
Measurement
menu by selecting “
Yes
” in the
Reset Measure
row.
When any key is released
(UP or DOWN)
the corresponding action is stopped.
Press key
(UP)
to control the anchor ascending
Press key
(DOWN)
to cast anchor
V=11.6 Vdc
V=11.6 Vdc
5 USE
Measure
R e s e t M e a s u r e
N o
U n i t s
F e e t
O f f
E x i t
6 TROUBLESHOOTING
FAULT
CAUSE
CORRECTIVE ACTION
Though
UP
or
DOWN
keys
are pressed, the instrument
doesn’t receive any signal from
the magnetic sensor for more
than 5 seconds.
Check the sensor electric connections.
Check if sensor operates properly.
If not, replace it.
Check the position of sensor and magnet on
gypsy and their distance.
Check the operation of electric
installation or anchor windlass.
The instrument’s power
supply voltage is lower than10Vdc.
Verify the battery charge or
operation of the electricssystem.
V=11.6 Vdc
V= 7.9 Vdc