5
2 Description
2.1 Operating Elements and Connections
1
Base Frame
with slotted holes Dia. 8.5 mm *290 mm.
2
Cartridge Tray
, to insert and fix the dual cartridge.
3
Pneumatic Connection
. The calibrated pneumatic hose OD 6 mm from the
controller (Regulated pressure:
I
) has to be connected here.
Pressure input limit is max. 6 bar (87 PSI). Make sure that the limit is kept.
4
Pressure Regulator 0-6 bar,
Component
A
and the other for Component
B
.
5
Pneumatic Gauge 0-10 bar,
Component
A
and the other for Component
B
.
6
Hand Lever Valve
Component
A
and Component
B
State of Switching = Position of the cylinders
– Piston forward
– Keep in position
– Piston backward
7
Product Level Display for
Component
A
and
B
in mm.
8
Pusher
Component
A
and
component
B
9
Proximity switch
, empty position of the cartridge, Component
A
, pin
assignment see section 8.2.
10
Proximity switch
, empty position of the cartridge, Component
B
, pin
assignment see section 8.2.
11
15 pin Sub D Connector, male
Connection to a control unit for the following signals:
– Low Level Sensor
12
C Type Cartridge Adapter,
available only on request.
13
F Type Cartridge Adapter,
available only on request.