Operating Theory

The cartridge or tube is pneumatically pressurized and product is ejected from the nozzle
while the trigger is pressed.
The quantity applied can be adjusted by turning the pressure regulator.

4

Inserting the Cartridge/Tube

•Unscrew the front retaining ring.
•Place the cartridge with the nozzle in the dispenser.
•Screw the tube into the tube adapter 989347 and then assemble it into the dispenser.
•Screw on front retaining ring and tighten.

Caution!
The retaining ring must completely cover the threads to seal the gun.

5

Connecting the Unit

•Connect the unit to an external pneumatic supply.

Caution!
When using cartridges, the pneumatic supply must not exceed 75 psi.
When using tubes, the pneumatic supply must not exceed 22 psi.

6

Nozzle Opening

Cut off the end of the nozzle as necessary. The amount cut off will determine the size
of the nozzle opening. It depends on the viscosity of the product and the desired
quantity to be applied.

Summary of Contents for HD10

Page 1: ...EQUIPMENT Instructions Loctite HD10 Pneumatic 300 ml Cartridge Dispenser Part Number 1714379 ...

Page 2: ... must be made by the consignee to the carrier and should be reported to the manufacturer 1 2 Items supplied 1 Pneumatic Dispenser 1 Equipment Manual 1 Air Line Adapter Fitting With Gasket 1 3 Container Types This dispenser is suitable to dispense 300 ml cartridges 250 ml tubes when item 989347 is purchased separately 2 Technical Data Pneumatic supply Pneumatic quality Filtered 5 μm oil free Max In...

Page 3: ...and then assemble it into the dispenser Screw on front retaining ring and tighten Caution The retaining ring must completely cover the threads to seal the gun 5 Connecting the Unit Connect the unit to an external pneumatic supply Caution When using cartridges the pneumatic supply must not exceed 75 psi When using tubes the pneumatic supply must not exceed 22 psi 6 Nozzle Opening Cut off the end of...

Page 4: ...den on components Do not immerse the handle Internal components will be damaged Make sure screws remain intact and tight 9 Troubleshooting Type of malfunction Possible causes Correction No or too little product No pneumatic supply present Pressure regulator is not properly adjusted Nozzle opening too small Hardening in the nozzle Provide pneumatic supply Turn pressure regulator clockwise Cut off t...

Page 5: ...Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO WARRANTY IS EXTENDED TO ANY EQUIPM ENT WHICH HAS BEEN ALTERED MISUSED NEGLECTED OR DAMAGED BY ACCIDENT EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER EXPRES...

Reviews: