![Loctite 1670898 Operation Manual Download Page 7](http://html1.mh-extra.com/html/loctite/1670898/1670898_operation-manual_1933816007.webp)
Operating Manual
- Page 7 -
1.1.3 Safety Precaution
In order to meet the requirements of the European Community (CE) safety
directives, the robot must be placed in an enclosure1 supplied by Henkel.
Make sure the robot is connected to a properly grounded power source before operating.
Keep away from any moving parts while the robot is running.
Loading and unloading of parts and material must only be done when the robot is at a
complete stop.
Changing of fixtures or tooling must be done with the power source disconnected.
The RB15 200D Gantry Robot should only be operated in an environment between 0 and 40
degrees Celsius with humidity of 20 to 95 percent and no visible condensation.
Do not store or setup the robot in an area where it is directly exposed to sunlight.
Do not operate the robot where electrical noise is present.
Only use a neutral chemical for cleaning the robot. Do not use alcohol, benzene or thinner as
it may damage the paint on the robot.
1.2Package Contents
In addition to this operating manual, the following items should be included with the robot.
1. Electrical Box
2. Robot
3. Dispense Cable (3 to 9 pin)
4. Teach Pendant Cable (9 pin to 9pin)
5. Syringe Holder
6. Shortage 7-pin
7. Power Cord
8. Screws for Syringe Holder
9. USB Memory Stick
Summary of Contents for 1670898
Page 5: ...Operating Manual Page 5 SECTION 1 Introduction ...
Page 8: ...Operating Manual Page 8 SECTION 2 Setup ...
Page 10: ...Operating Manual Page 10 2 3Mount on Production Line ...
Page 11: ...Operating Manual Page 11 SECTION 3 Tour of Robot ...
Page 13: ...Operating Manual Page 13 SECTION 4 Tour of Teach Pendant ...