101+ DELAYED EGRESS
MAGNETIC LOCKING SYSTEM
16
FORM 10111 Rev. C
04/11/2002
TO CHANGE CODES
Master Code *...1 *...Old Code*...New Code (3-8 digits) *...* (to end)
MORE CODES CAN BE CHANGED
BY RETURNING HERE.
TO DELETE CODES WITH ALARM/ATR NOTICE:
Codes will be not be allowed to function but will remain in memory. When the code is used, the lock will go into alarm, the alarm relay will close, the audible
will sound and the LED will illuminate red. The door will not unlock. It will stay in alarm until a valid user code, TouchEntry Key or reset input will silence the
alarm. If the ATR option is present and the unit was programmed by computer, an access attempt will show in the audit trail.
Master Code *...55 *...Old Code *...* (to end)
MORE CODES CAN BE DELETED
BY RETURNING HERE.
TO DELETE CODES
Master Code *...5 *...Old Code *...* (to end)
MORE CODES CAN BE DELETED
BY RETURNING HERE.
MANUAL PROGRAMMING - KEYPAD
When manually programming the 101+ model lock, using a keypad, the keypad must first be initialized. It is a recommended that the factory default Master Code be
changed. Doing so will delete all factory default codes and ensure the security of the system. After entering the Master code the LEDs on the keypad will flash. They will
also flash each time that * is entered. Wait for the LED to stop flashing before entering the next sequence.
TO CHANGE MASTER CODE
Master Code *...7 *...New Master Code (5-8 digits)*...New Master Code *
TO ADD NORMAL ACCESS CODES
-
Will unlock door for relock time delay period. Will also reset lock after an alarm condition.
Master Code *...3 *...New Code (3-5 digits) *...* (to end)
UP TO 150 NEW CODES CAN BE
ADDED BY RETURNING HERE.