101+ DELAYED EGRESS
MAGNETIC LOCKING SYSTEM
15
FORM 10111 Rev. C
04/11/2002
TO CREATE MASTER TEK (FOR USE WITH COMPUTER PROGRAMMING)
The master TEK is used to initialize programming (like a password to access programming mode).
A. Set SW4 dipswitch #1 to ON (if it is off).
B. Press and hold SW3 until two beeps are heard.
C. Touch a TEK key to the reader within ten seconds. The lock will indicate acceptance with two beeps. This will be the Master TEK.
D. Return SW4, #1 to its original position.
NOTES:
1.
Refer to instructions included with the programmer/software that you will use to program for more
information regarding programming.
2.
The Master TEK is used for initiating programming. It will not unlock the door.
3.
Unlike some other Locknetics products, creating a master TEK will not delete the factory default codes.
They must be manually deleted.
“SYSTEM 7” PROGRAMMING:
This procedure will allow up to seven TouchEntry Keys to be programmed into a lock equipped with a TouchEntry Key reader of SelectEntry Keypad. Keys will be of the
Normal Access type and will unlock the unit for the relock time delay. The TEKs will also reset the lock if it is in an alarm condition.
A. Set SW4-1 to OFF (if it is on)
B. Press and hold SW3 until you hear two beeps. Release SW3.
C. Touch each of the TEKs to the reader. Two quick beeps will sound each time a key has been accepted.
D. After entering up to seven TEKs wait 10 seconds for programming to end. One quick beep will indicate that programming has ended.
E. Return SW4-1 to its original position, if required.
NOTE:
Whenever new “System 7” TEKs are entered, the old ones are erased. Also, whenever computer programming is done, or memory is erased, all “System 7”
TEKs are erased.
KEYPAD/100CAB INITIALIZATION (REQUIRED TO ENABLE KEYPAD TO FUNCTION)
It is necessary to initialize the keypad/100CAB any time that the memory is erased.
A. Set SW4 dipswitch #1 to ON.
B. Press and hold switch SW3 for two quick beeps of the audible..
C. Push each button in order, starting with the 1-2 button, and including the *.
*
Wait for LEDs to stop flashing before pushing next button.
* Waiting for longer than 7 seconds will terminate initialization.
D. After the last button is pressed, the audible will beep three times and the LEDs will
flash indicating that programming has ended.
E. Return SW4 dipswitch #1 to its original position.
DEFINITION OF CODE/TEK FUNCTIONS AND FACTORY DEFAULTS:
MASTER
97531
Allows access to programming functions. Will not release lock.
NORMAL
13579
Unlocks lock for relock time delay. Will reset lock in alarm condition.
ACCESS
TOGGLE
135135
Unlocks the lock until same or another Toggle Code is entered.
LOCKOUT
9115
“Freezes” the lock in its present condition, either locked or unlocked, until the same or
another Lockout Code/TEK is entered.
ONE-TIME ACCESS
No factory default. This type of code/TEK will allow access only once.
It will then become deleted from memory.
SUPERVISED ACCESS
No factory default. This type of code/TEK allows access only when used with another
Supervised Access Code/TEK. The second code/TEK must be entered within five
seconds of the first one. The order that they are entered does not matter.
FACTORY DEFAULT