INSTRUCTION MANUAL
STEP 6 - Adjusting doors
The final process is to align the doors so that they fit evenly over the
locking pins and are in line with each other.
Once the FUYL Cell is secured it may be necessary to re-align the
doors so that they fit properly. Using the small Allen key, adjustment
is made by loosening the small socket bolts inside the door and
either lifting the door up or down as is necessary, and retightening
the socket bolts.
OPTIONAL STEP - Alternate FUYL Cell stack
It is possible to assemble the FUYL Cell stack so that the
doors do not all face the front.
As the FUYL Cell is assembled one or more of the FUYL
Cells can be rotated prior to being bolted to the stack below.
The locating holes for the M6 socket bolts are uniform on
the corners enabling the FUYL Cells, joiners and pedestal
to be joined in any orientation.
HOWEVER, care must be taken during this alternate
assembly as the grommets through which the power leads
run will be offset, and the lead(s) from the top FUYL Cells
will not reach down into the bottom of the stack.
These issues are overcome by:
a. Running the lead from the FUYL Cell above, through
the joiner ring and down through the grommet prior to
assembling the FUYL Cells together, and
b. Adding a short 1 or 2m extension cord (not supplied)
from the upper FUYL Cells to get sufficient cord length.
Plugs and sockets can be ‘hidden’ behind the left hand
access panels.