background image

 

8

·Get the desired chain tension by adjusting the chain bolts. 

·Reliable rolling code technology 

·Emergency release key in case of power failure 

·Stop/Reverse in case of obstruction during gate opening/closing 

·Built in adjustable auto-close (0, 30, 60, 90 seconds) 

·Built in max. 90 seconds Motor running time (MRT) for multiple safety protection 

·Reliable electromagnetism limit for easy adjustment 

·Can be equipped with wide range accessories 

 
 
 

Installation Overview 

 

 
 

Installation of the Operator 

Caution:  
*Be sure that the operator is installed in a level and paralleled position and is properly secured. 
Improper installation could result in property damage, severe injury, and/or death. 
* Before starting installation, ensure that there is no point of friction during the entire movement of 
the gate and there is no danger of derailment. 
* Ensure that the 

Warning Signs

 are present. 

 
Necessary Tools: 

The following tools may be necessary to install the Gate operator. You will need 

screwdrivers, an electric drill, wire cutters and a wire stripper, a socket set, and possibly access to a welder.

 

When install the operator, you should build a concrete pad to support the base plate of operator in order to 
maintain proper stability. 

The installation proceeds are as follows: 
1.

Dig a hole for a concrete pad which should be approximately 60 x 32 x 35cm (24

x 13

x 14

). It may 

protrude 10 cm (4”) above ground and 25 cm (10”) in depth underground. Increase the pad height if 

Summary of Contents for SCG 18H

Page 1: ...www WholesaleGateOpener com Rev 11a...

Page 2: ...7 Installation Overview 8 Installation of the Operator 8 Manual Operation 9 Installation of chain and chain brackets 10 Installation of the Limit Switch 11 Connecting of the Control Board 12 Setting...

Page 3: ...carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to...

Page 4: ...lied for exposed rollers B The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be...

Page 5: ...side and outside of a vehicular horizontal slide gate 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located...

Page 6: ...es not bind or drag on the ground The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping The opening and closing gate stops are positioned W...

Page 7: ...6 Parts List...

Page 8: ...rbed power SCG18H 370W SCG21H 550W Gate moving speed 7 9 second 20 cm second Max gate weight SCG18H 800KGS SCG21H 1200KGS Max torque SCG18H 24Nm SCG21H 35Nm Environmental conditions From 15 C to 40 C...

Page 9: ...d result in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailmen...

Page 10: ...oncrete become harden 5 Mount the base plate to the concrete Pad It s only temporary installation Further adjustment will be required when install the chain 6 Mount the chain box to the base plate by...

Page 11: ...emporarily Nuts will be further adjusted for a proper chain tension later 3 Connect second chain bolt with another end of chain from chain box then attach bolt to the L bracket on opposite end of gate...

Page 12: ...hand Locate and install the magnet bracket so that the operator will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install th...

Page 13: ...W wire of the limit switches should be connected into the 9 terminal 4 Alarm Lamp One wire of the alarm lamp should be connected into the 4 terminal another should be connected into the 5 terminal 5 P...

Page 14: ...13...

Page 15: ...of the motor in midway mode auto close time of the gate operator and fast change the open close direction which is determined by the position of the gate operator installed DIP Switch 1 2 Running tim...

Page 16: ...other word the stall force level is higher the reversing sensitivity level is lower Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles...

Page 17: ...citor c The electric component on the control board may be damaged Replace the electric component or replace the control board 2 The gate will not open or close a The power switch is OFF Make sure the...

Page 18: ...close a Photocell is obstructed Remove obstruction b The limit switch is failed Disconnect the limit switches and try it again c The start capacitor of the motor is failed Replace the capacitor d The...