background image

 

3

Important Safety Instructions 

 

WARNING – To reduce the risk of injury or death: 

1) READ AND FOLLOW ALL INSTRUCTIONS. 
2) Never let children operate or play with gate controls. Keep the remote control away from children. 
3) Always keep people and objects away from the gate. NO PERSON SHOULD CROSS THE PATH OF 
THE MOVING GATE. 
4) Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an 
object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate 
operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 
5) Use the emergency release only when the gate is not moving. 
6) KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person 
make repairs to gate hardware. 
7) The entrance is for vehicles only. Pedestrians must use separate entrance. 
8) SAVE THESE INSTRUCTIONS. 

Safety Instructions for Installation 

A. Install the gate operator only when: 
1) The operator is appropriate for the construction of the gate and the usage Class of the gate, 
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum 
of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through 
the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open 
position, 
3) All exposed pinch points are eliminated or guarded. 
4) Guarding is supplied for exposed rollers. 
B. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied 
with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian 
usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire 
path of travel of the vehicular gate. 
C. The gate must be installed in a location so that enough clearance is supplied between the gate and 
adjacent structures when opening and closing to reduce the risk of entrapment.   
D. The gate must be properly installed and work freely in both directions prior to the installation of the gate 
operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate. 
E. For gate operators utilizing Type D protection: 
1) The gate operator controls must be placed so that the user has full view of the gate area when the gate is 
moving. 
2) The placard provided marked in letters at least 1/4-in (6.4-mm) high with the word 

WARNING

 and the 

following statement or the equivalent: “ Moving Gate Has the Potential of Inflicting Injury or Death – Do Not 
Start Gate Unless Path is Clear” shall be placed adjacent to the controls, 
3) An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed. 
4) No other activation device shall be connected. 
F. Controls intended for user activation must be located at least ten feet (10’) away from any moving part of 
the gate and where the user is prevented from reaching over, under, around or through the gate to operate 
the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 

Summary of Contents for SCG 18H

Page 1: ...www WholesaleGateOpener com Rev 11a...

Page 2: ...7 Installation Overview 8 Installation of the Operator 8 Manual Operation 9 Installation of chain and chain brackets 10 Installation of the Limit Switch 11 Connecting of the Control Board 12 Setting...

Page 3: ...carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to...

Page 4: ...lied for exposed rollers B The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be...

Page 5: ...side and outside of a vehicular horizontal slide gate 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be located...

Page 6: ...es not bind or drag on the ground The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping The opening and closing gate stops are positioned W...

Page 7: ...6 Parts List...

Page 8: ...rbed power SCG18H 370W SCG21H 550W Gate moving speed 7 9 second 20 cm second Max gate weight SCG18H 800KGS SCG21H 1200KGS Max torque SCG18H 24Nm SCG21H 35Nm Environmental conditions From 15 C to 40 C...

Page 9: ...d result in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailmen...

Page 10: ...oncrete become harden 5 Mount the base plate to the concrete Pad It s only temporary installation Further adjustment will be required when install the chain 6 Mount the chain box to the base plate by...

Page 11: ...emporarily Nuts will be further adjusted for a proper chain tension later 3 Connect second chain bolt with another end of chain from chain box then attach bolt to the L bracket on opposite end of gate...

Page 12: ...hand Locate and install the magnet bracket so that the operator will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install th...

Page 13: ...W wire of the limit switches should be connected into the 9 terminal 4 Alarm Lamp One wire of the alarm lamp should be connected into the 4 terminal another should be connected into the 5 terminal 5 P...

Page 14: ...13...

Page 15: ...of the motor in midway mode auto close time of the gate operator and fast change the open close direction which is determined by the position of the gate operator installed DIP Switch 1 2 Running tim...

Page 16: ...other word the stall force level is higher the reversing sensitivity level is lower Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles...

Page 17: ...citor c The electric component on the control board may be damaged Replace the electric component or replace the control board 2 The gate will not open or close a The power switch is OFF Make sure the...

Page 18: ...close a Photocell is obstructed Remove obstruction b The limit switch is failed Disconnect the limit switches and try it again c The start capacitor of the motor is failed Replace the capacitor d The...

Page 19: ...www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2010 2012 LockMaster All Rights Reserved...