16
How to learn or erase the remote
Learn the remote
Press and release the learn button, the
REM
LED
light will be on, then press the key in the
remote twice in 2 seconds, the
REM LED
light will flash for 4 seconds. Now the
remote has been learnt successfully.
Erase all the remote codes
Press and hold the learn button until the
REM
LED
light is off. Now all remote codes have been erased.
How to use the remote to control the operator
Key A
is used to operate the operator to work alternately (open-stop-close-
stop-open).
When the Midway Mode function is enabled,
Key B
is used to achieve the
Midway Mode function (open the gate for the pre-setting time). When the
Midway Mode function is disabled, the operator works alternately (open-stop
-close-stop-open) by pressing
Key B
.
Troubleshooting
Have a multimeter to check voltage and continuity. Use caution when checking high voltage terminals.
1. Motor only runs toward one direction.
a. The limit switch is failed. Disconnect the limit switches and try it again.
b. The start capacitor of the motor is failed. Replace the capacitor.
c. The electric component on the control board may be damaged. Replace the electric component or replace
the control board.
2. The gate will not open or close.
a. The power switch is OFF. Make sure the power switch is ON.
b. The limit switches are failed. Disconnect the limit switches and try it again.
c. Connecting wires or terminal blocks are too loose. Check the connecting wires and terminal blocks.
d. The motor has been damaged. Replace the motor if necessary.
e. The thermal protector is working because the high temperature after long working time. Please wait for 20
minutes to let the motor become cold.
f. The electric component on the control board has been damaged. Replace the electric component or
replace the control board.
3. Remote control does not work.
a. The distance you use the remote is too far away from the opener. Try it again closer.
b. Remote control is not suitable for receiver. After making sure the codes are correct, erase remote controls
and then re-program the codes in the device.
c. Broken receive board. Replace receive board.
d. The indicator light of remote control is not on. Check the battery in your remote control. Replace the
battery if necessary.
4. When you open or close the gate by pressing key #1 and key #2 which have been programmed,