background image

      

Dual Fuel Supplemental Manual

Please read before proceeding

Installer – 

Read all instructions, including 

this manual, the Crest Installation and 
Operation Manual and the Crest Service 
Manual, before installing.  Perform steps 
in the order given.

User – 

This manual is for use only 

by a qualified heating installer/
service technician.  Refer to the User’s 
Information Manual for your reference.

Have this boiler serviced/inspected by 
a qualified service technician, at least 
annually.

Failure to comply with the above could 
result in severe personal injury, death or 
substantial property damage.

Failure to adhere to the guidelines on this 
page can result in severe personal injury, 
death, or substantial property damage.

When servicing boiler –

• To avoid electric shock, disconnect electrical supply 
  before performing maintenance.

• To avoid severe burns, allow boiler to cool before 
 performing 

maintenance.

Boiler operation –

• Do not block flow of combustion or ventilation air to 
 the boiler.

• Should overheating occur or gas supply fail to shut off, 
  do not turn off or disconnect electrical supply to 
  circulator.  Instead, shut off the gas supply at a location 
  external to the appliance.

• Do not use this boiler if any part has been under water.  
  The possible damage to a flooded appliance can be 
  extensive and present numerous safety hazards.  Any 
  appliance that has been under water must be replaced.

When calling or writing about the boiler 
– Please have the boiler model and serial 
number from the boiler rating plate.

Consider piping and installation when 
determining boiler location.

Any claims for damage or shortage in 
shipment must be filed immediately 
against the transportation company by 
the consignee.

Factory warranty (shipped with unit) does 
not apply to units improperly installed or 
improperly operated.

3

If the information in this manual is not 
followed exactly, a fire or explosion may 
result causing property damage, personal 
injury or loss of life.

This appliance MUST NOT be installed in 
any location where gasoline or flammable 
vapors are likely to be present.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do 
  not use any phone in your building.
• Immediately call your gas supplier 
  from a near by phone.  Follow the 
  gas supplier’s instructions.
• If you cannot reach your gas supplier, 
  call the fire department.
• 

Installation and service must be 

 performed by a qualified installer, 
  service agency, or the gas supplier.

 WARNING

 NOTICE

 WARNING

 WARNING

 

Summary of Contents for Crest 1251

Page 1: ...along with the Crest Installation and Operation Manual and the Crest Service Manual before installing Perform steps in the order given Failure to comply could result in severe personal injury death o...

Page 2: ...situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in prope...

Page 3: ...ernal to the appliance Do not use this boiler if any part has been under water The possible damage to a flooded appliance can be extensive and present numerous safety hazards Any appliance that has be...

Page 4: ...o flow only if the gas valves are powered and combustion air is flowing 7 Small propane valve Valve 1 Propane The small propane gas valve senses the negative pressure created by the blowers allowing g...

Page 5: ...tes Department of Energy 2 Net AHRI ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be added for normal piping and pickup Rati...

Page 6: ...to the appliance 13 Remove the manometer from the pressure tap on top of the gas valve Remove the 1 8 3 mm field supplied fitting and reinstall the pipe plug removed in Step 3 DO NOT adjust or attemp...

Page 7: ...e replacement The gas valve MUST NOT be replaced with a conventional gas valve under any circumstances As an additional safety feature the gas valves have flanged connections to the venturis and blowe...

Page 8: ...oming gas pressure less than 4 inches w c 99 kPa If none of the above corrects the problem refer to the Troubleshooting Section of the Crest Service Manual Check system and boiler Check water piping 1...

Page 9: ...inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set...

Page 10: ...6 Insert the probe from a combustion analyzer into the hole left by the removal of the fitting 7 Once the boiler has modulated up to rate measure the combustion The values should be in the range list...

Page 11: ...ot in use FIG 2 3 Figure 2 3 Shutoff Valves NATURAL SHUTOFF VALVE PROPANE SHUTOFF VALVE DIR 2000508189 4 Turn on the shutoff valve for the one in use 5 Turn the main power ON 6 Using the Touch Screen...

Page 12: ...2 INTEGRATED CONTROL CN3 4 X8 15 X7 7 X8 11 X8 6 X8 16 X8 7 X8 17 X8 1 X8 3 X8 8 X8 2 X8 4 X8 9 X7 1 X7 5 GROUND X11 LCD DISPLAY X4 X5 1 X5 7 X5 2 X5 8 X5 3 X5 9 X5 4 X5 10 X5 5 X5 41 X5 6 CN3 12 BAS...

Page 13: ...R BL X6 18 X6 8 X1 8 G X6 9 MAIN BLOWER BLOWER R BK GY W T BK X2 3 X1 7 X1 10 X1 5 TRANSITION FLAME SENSE LG CON BRD FLAME SENSE SPARK GENERATOR SPARK ROD X2 5 FLUE DAMPER TRANSFORMER X13 4 FLUE DAMPE...

Page 14: ...Dual Fuel Supplemental Manual Notes 14...

Page 15: ...15 Dual Fuel Supplemental Manual Notes...

Page 16: ...Revision Notes Revision A Change 500001029 initial release MM 100268179_DIR 2000509263 Rev A 10 15...

Reviews: