8
(3) Prepare an air compressor. Be sure to place an air filter and an air regulator between the
compressor and the air riveter.
(4) Set up 0.49 to 0.59 Mpa (5 to 6 kgf/cm
2
) as air pressure.
Too much pressure may cause damage to the tool. Too low
pressure may cause incomplete rivetting or incomplete
cutting.
(5) Make sure that the tool works properly.
After connection with air, make sure that the tool works smoothly without oil leak by idle
run (operating 2 or 3 times without rivets).
The tool needs careful cleaning and maintenance if it is not used
for a long time. (Ref: “5.1 Frame head and jaw case”) After
cleaning and maintenance, vacuum mechanism must be operated
before use.
Air Filter
Air Compressor
Pressure
Regulator
Complete Air Supply System
3. Preparation Before Use