15
Tank Unit
Nozzle Unit
Nozzle B
Nozzle A
O-ring
Hole
5.5 NOZZLE
UNIT
If dust is accumulated at nozzle unit, power of vacuuming rivet’s shaft weakens. If power of
vacuuming shaft is getting weak, check as following procedure:
●
Disassembly
(1) Stop air supply.
(2) Remove the tank unit or the chute hose.
(3) Remove the nozzle unit from the main unit by
a spanner.
(4) Disconnect the nozzle unit A from the nozzle
unit B.
They are connected a little
tight. Therefore, disconnect
them by pliers. Be careful not
to hurt the O-ring attached with
the nozzle A.
●
Cleaning
(5) Clean carefully inside of the tube of the nozzle A and the nozzle B, and the small hole of the
nozzle B.
●
Assembly
(6) Assemble parts in reverse procedure of disassembly.
5. Cleaning and Maintenance