Figure 39: Extract from a coverage test result file, a token number helps to identify the test performed
Figure 40: Coverage test result file extract, test performance expressed in messages received against messages lost for each SF
Safely closing the Piconode
To ensure water tightness and durability of the data logger, the polycarbonate cover has to be fully closed by lifting
it up and pressing until you hear a ‘click’ sound. The cable gland is to be tightened with a 19 mm spanner to ensure
watertightness (Figure 41).
Figure 41: Tightening of the Piconode cable gland
If the above conditions are not met, IP67 rating cannot be guaranteed. Should the data logger need further sealing
due to placement in an extreme environment or in a floodable manhole, additional sealants will be required to
close the box. See
Annex 10 LS G6 Dataloggers installation on manholes
Maintenance
Piconode Firmware Upgrade Procedure
When a new version of the app is available, DLog will display an automatic message asking the customer to
upgrade it. To be able to have the latest Dlog version, the mobile phone or tablet in which the app is installed needs
to have Internet, otherwise the customer should contact Loadsensing Technical Support for assistance.
22