START UP MANUAL
13
QUICK LOAD SERVO S2
4.1.2 Tubing
With regard to loading the tubing, standard-feeding pushers may be used, as the inside
diameter of the tubes is smaller than the outside diameter of the pushers.
If this is not the case, there are two ways to proceed :
1.
The first one consists in making caps
(A) and installing them behind the tubes
(B).
For the caps to stay in place while the
bar is rotating, they should be fitted
with an O-Ring.
2.
The second one consists in replacing
the head of the pusher (C) with a
special nose (D), 130 mm in diameter
(available for pusher
Ø
25 mm only).
Des.
Ord. Nr
Description
D 021.11.104_130 130mm disk
To feed properly inside the spindle (F),
the outside diameter of the disk (D)
should be turned to a diameter 4 mm
(.015") smaller than that the inside
diameter of the spindle (F) or of the
spindle liner. The head must be adjusted
before it is mounted onto the pusher.
Procedure :
C
Switch the bar feed system in
STOP mode (remote station).
•
Undo the set screw (E) holding
the head (C) onto the pusher.
•
Remove standard head.
•
Install special disk (D), by
pushing it to a stop in the pusher.
•
Secure disk with the set screw.
Summary of Contents for QUICK LOAD SERVO S2