CHAPTER 5: PNEUMATICS
5-7
ECOLOAD S2
6. MAINTENANCE
The pneumatic system should be regularly maintained in order to ensure the system is powered by
qualified compressed air. We recommend the user to check the F.R.L. combination as instructed below
every week.
6.1. Check the condensate collector
The condensate collector is a measure of quality of the compressed air. A qualified air should not produce
any condensate inside the collector.
The F.R.L. combination should never be a replacement of air dryer!!!
The collector has an automatic drain plug. When there is no pressure inside the F.R.L. system, the drain
plug is activated by the spring and the condensate released.
For users which always connect the compressed air, a manual draining is needed. Whenever the
condensate is found inside the collector, drain the condensate by pushing the plug upward and check the
humidity control system.
6.2. Check lubricator
The oil consumption varies with the bar feeder applications. The oil height should not exceed half of the
oil cup height. It is recommended to use oil ISO VG 32 only. When the oil is less than 30%, follow the
procedures below to refill it.
Disconnect the air inlet tube.
Remove the plug and fill the oil up to the position shown on the figure.
For the best performance, the oil should drop once every pusher complete forward/backward
moving cycle. If the working environment is humid or lathe does not installed air filter system users
can drop more. Adjust the amount according to actual production conditions.
Connect the air inlet tube and turn air source on.
Decreasing oil
dribbling
Oil dribbling nozzle
Increasing oil
dribbling
Oil refill plug
Oil level
Summary of Contents for Eco Load S2
Page 1: ...LNS SA 2534 Orvin Switzerland www LNS group com Instruction manual ENG 9 ECO 01 ...
Page 2: ......
Page 5: ...CHAPTER 1 BASIC NOTIONS 1 1 ECOLOAD S2 CHAPTER 1 BASIC NOTIONS ...
Page 12: ...1 8 CHAPTER 1 BASIC NOTIONS ECOLOAD S2 ...
Page 13: ...CHAPTER 2 TECHNICAL DATA 2 1 ECOLOAD S2 CHAPTER 2 TECHNICAL DATA ...
Page 17: ...CHAPTER 2 TECHNICAL DATA 2 5 ECOLOAD S2 2 3 Z axis retraction system ˋˆˊ ˊˋˊ ˌˊ ˉ ˁˈ ʳ ˆˇ ˈ ...
Page 19: ...CHAPTER 3 SETTING INTO OPERATION 3 1 ECOLOAD S2 CHAPTER 3 SETTING INTO OPERATION ...
Page 36: ...3 18 CHAPTER 3 SETTING INTO OPERATION ECOLOAD S2 ...
Page 37: ...CHAPTER 4 ELECTRICS 4 1 ECOLOAD S2 CHAPTER 4 ELECTRICS ...
Page 43: ...CHAPTER 4 ELECTRICS 4 7 ECOLOAD S2 4 2 Circuit diagram ...
Page 45: ...CHAPTER 4 ELECTRICS 4 9 ECOLOAD S2 5 2 PLC I O DIAGRAMS ...
Page 54: ...4 18 CHAPTER 4 ELECTRICS ECOLOAD S2 ...
Page 55: ...CHAPTER 5 PNEUMATICS 5 1 ECOLOAD S2 CHAPTER 5 PNEUMATICS ...
Page 57: ...CHAPTER 5 PNEUMATICS 5 3 ECOLOAD S2 2 PNEUMATIC CIRCUIT DIAGRAM ...
Page 62: ...5 8 CHAPTER 5 PNEUMATICS ECOLOAD S2 ...
Page 63: ...CHAPTER 6 GENERAL DESCRIPTION 6 1 ECOLOAD S2 CHAPTER 6 GENERAL DESCRIPTION ...
Page 77: ...CHAPTER 7 OPERATION 7 1 ECOLOAD S2 CHAPTER 7 OPERATION ...
Page 98: ...7 22 CHAPTER 7 OPERATION ECOLOAD S2 ...
Page 99: ...CHAPTER 8 TROUBLESHOOTING GUIDE 8 1 ECOLOAD S2 CHAPTER 8 TROUBLESHOOTING GUIDE ...
Page 109: ...CHAPTER 9 APPENDICES 9 1 ECOLOAD S2 CHAPTER 9 APPENDICES ...