3 (8)
EN.33.C.134.1512
Assembly instructions | LK Minishunt M60
Assembly of LK Actuator
Wireless or wired electronic room control for
LK Minishunt M60 are available as accessories.
The enclosed thermostat with capillary tube con-
nected sensor is then replaced with an electric
LK Actuator and is installed according to the se-
quence below.
Click!
Assembly of supplied thermostat
To install the supplied thermostat with capillary
tube connected sensor, dismantle the hand actua-
tor and the black threaded adapter according to
the sequence below. The capillary tube connected
sensor is preferably placed on a interior wall. As
accessory a thermostat with 5 m capillary tube,
alternatively LK’s electronic wired or wireless
room control can be used.